background image

SATEL AXD-200 

14. Depending on the detector type and configuration, make sure that the LED comes on: 

 

AMD-200

–  after moving the magnet away (opening the window or door), 
–  after violating the detector connected to the additional input M1. 

 

AMD-201

–  after moving the magnet away (opening the window or door), 
–  after violating the detector connected to the additional input M1. 

 

AMD-202

–  after moving the magnet away (opening the window or door), 
–  after violating the detector connected to the additional input M1, 
–  after raising / lowering the roller shutters supervised by the roller shutter detector. 

 

AVD-200

–  after moving the magnet away (opening the window or door), 
–  after impact against the surface protected by the detector. 

The shock detector range depends on the type of surface on which the detector is 
installed. The specified detection range (up to 3 m) should be considered an 
approximate value. The actual range should be determined experimentally after 
securing the detector to the surface. 

 

ARD-200

 – after changing the detector position. 

 

AFD-200

 – after submerging the flood probe in water. 

15. For the water flood detector, when the test is done, secure the FPX-1 probe as shown in 

Fig. 8. 

3.1  Selecting detector type 

1.  Install the battery in the detector. The detector LED will start flashing rapidly. 
2.  Within 10 seconds of inserting the battery, knock 3 times on the detector enclosure. The 

LED will flash to indicate the selected detector type – see Table 2

 

Number of LED flashes 

Detector type 

Magnetic contact (AMD-200) 

Dual channel magnetic contact (AMD-201) 

Magnetic contact with input for roller shutter detector 
(AMD-202) 

Shock detector and magnetic contact (AVD-200) 

Reorientation detector (ARD-200) 

Temperature detector (ATD-200) 

Water flood detector (AFD-200) 

Table 2. 

 

If you do not want to change the detector type, wait for about 10 seconds. If there are 
no impacts within 10 seconds, the detector type selecting procedure will be 
terminated. The LED will indicate once more what type is saved in the detector 
memory. 

Содержание AMD-100

Страница 1: ...AXD 200 Wireless multipurpose detector Firmware version 1 00 axd 200_en 03 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Страница 3: ...d in the ABAX system as AMD 100 This manual applies to the detector with firmware version 1 00 which is supported by ABAX 2 ACU 220 ACU 280 controller ARU 200 repeater ABAX ACU 120 ACU 270 controller...

Страница 4: ...BAX system the detector is identified as AMD 101 AMD 202 Magnetic contact with input for roller shutter detector Detects open door window etc Input for connecting a wired roller shutter detector Input...

Страница 5: ...ate periodical communication Additional communication may take place as a result of alarm see Operating modes Alarms Described below are circumstances in which the detector reports alarm depending on...

Страница 6: ...ht at which the probe is installed The detector reports end of flooding a few seconds after the water level drops below the height at which the probe is installed Operating modes Active information ab...

Страница 7: ...tor inside after opening the enclosure terminal block COM common ground M1 input supported in the case of the AMD 200 AMD 201 AMD 202 and AFD 200 detectors It allows connection of an NC type detector...

Страница 8: ...frame for this purpose This will reduce the probability of the detector being flooded accidentally when the window is partially or full open The following tools will be useful to mount the detector b...

Страница 9: ...location of installation 7 Open the detector enclosure Fig 3 8 If detectors or flood probe are to be connected to the additional input terminals make a hole in the enclosure base run wires through the...

Страница 10: ...8 AXD 200 SATEL...

Страница 11: ...d be determined experimentally after securing the detector to the surface ARD 200 after changing the detector position AFD 200 after submerging the flood probe in water 15 For the water flood detector...

Страница 12: ...p to 2000 m ACU 280 up to 1200 m ABAX up to 500 m Battery CR123A 3 V Battery life expectancy up to 2 years NC type input sensitivity 240 ms Temperature measurement range 10 C 55 C Temperature measurem...

Отзывы: