2 AFD-100
SATEL
Electronics board
Figure 1 shows the inside of the detector.
CR123A lithium battery.
tamper
switch.
terminals for the flood sensor connection.
The LED is placed on the other side of the electronics board.
Alarms
The detector reports alarm in the following cases:
flood detection,
opening the tamper switch (tamper alarm).
Operating modes
Active
– information about each alarm is sent immediately.
Passive
– information about tamper alarm is sent immediately, while
information about flood only during the polling time.
Test mode
If you want to test the detector, you can remotely enter the test
mode. When in the test mode, the detector LED is working.
LED
The LED is working for 2 minutes after battery is inserted, as well as in the test mode. The
LED indicates:
polling – short flash (80 milliseconds),
alarm – ON for 2 seconds.
Battery status control
When the battery voltage is below 2.75 V, information about low battery is sent during each
transmission.
Note: For additional information about the detector and its configuration please refer to the
manual for ABAX wireless system controller.
4. Installation
The detector is designed for indoor installation.
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
1. Open the detector enclosure (Fig. 2).
2. Install the battery and add the device to the wireless system (see the ACU-100 / ACU-250 /
ACU-120 / ACU-270 controller manual or the INTEGRA 128-WRL / VERSA control panel