AFD-100
WIRELESS WATER FLOOD DETECTOR
afd100_en 08/17
The AFD-100 wireless detector senses the presence of water leaks or flooding in rooms with
plumbing. The detector is designed for use as part of the ABAX two-way wireless system.
This manual applies to the detector with firmware version 5.00, which is supported by:
ACU-120 / ACU-270 controller,
ACU-100 / ACU-250 controller with firmware version 4.03 2014-05-15 (or newer),
ARU-100 repeater with firmware version 2.00 2014-05-15 (or newer),
INTEGRA 128-WRL control panel with firmware version 1.12 2013-12-20 (or newer).
1. Features
External flood sensor.
LED indicator enabled in test mode.
Tamper protection against cover removal and tearing enclosure from the wall.
Battery status control.
2. Specifications
Operating frequency band ...................................................................868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) ............................................................ up to 500 m
Battery ................................................................................................................... CR123A 3 V
Battery life expectancy...................................................................................... approx. 3 years
Flood sensor cable length.................................................................................................... 3 m
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range.............................................................................-10 °C...+55 °C
Enclosure dimensions....................................................................................26 x 112 x 29 mm
Weight................................................................................................................................. 96 g
Hereby, SATEL sp. z o.o., declares that this detector is in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU.
The declaration of conformity may be consulted at www.satel.eu/ce
3. Description
The detector is designed to be used in spaces where there is a risk of leakage from
plumbing. Approximately 5 seconds after the water level reaches the height at which
electrodes of the flood sensor are installed, the detector will start signaling flooding. A few
seconds after the water level drops below the height at which electrodes of the flood sensor
are installed, the flood signaling will stop.