ACU-100 SATEL
13
Consecutive module number
Module address Control input numbers Output numbers
1 0
5-8
9-16
2 1
9-12
17-24
3 2
13-16
25-32
4 3
17-20
33-40
5 4
21-24
41-48
Table 4.
Fig. 6. Example of connecting two ACX-100 modules to ACU-100 controller.
The module TMP terminals must be connected to the control panel tamper circuit.
4.5 A
DDING NEW WIRELESS DEVICES
4.5.1 D
LOAD
10
and
D
LOAD
X
programs
In order to add a new wireless device to the system, do the following:
1. Press the N
EW DEVICE
button in the program.
2. A window will appear, in which you should enter the 7-digit serial number of the device
being added. The serial number can be found on the electronics board or on the housing.
Each ARF-100 tester has the serial number 0000500.
3. Depending on which device is to be added to the system:
−
turn on power supply of the ACX-200 expander – immediately after start-up (power-up),
the expander will send a single signal to enable registration,
Wireless system controller
ACU-100
First expansion module
ACX-100
address 0
Second expansion module
ACX-100
address 1
module
power supply