![Satel abax 2 ARU-200 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/satel/abax-2-aru-200/abax-2-aru-200_quick-start-manual_1200762007.webp)
SATEL
ARU-200
5
The ARF-200 tester makes it possible to check the radio signal strength at the place of
future installation without having to put the repeater there.
8. Power down the repeater.
9. Remove the cover and disconnect the temporary power supply.
10. Place the enclosure base against the wall and mark the location of mounting holes.
11. Drill the holes for wall plugs (screw anchors).
12. Run the power wires through the opening in the enclosure base.
13. Using wall plugs and screws, secure the enclosure base to the wall. Proper wall plugs
must be selected for the type of mounting surface (different for concrete or brick wall,
different for plaster wall, etc.).
14. Attach the power wires to the repeater terminals: the phase wire to L terminal, the neutral
wire to N terminal (secure the cable using the element provided for this purpose
– see
Fig. 4).
15. Connect the battery to the connector (the repeater will not start on connecting the battery
alone).
16. Replace the cover and lock it with screws.
17. Energize the circuit to which the repeater is connected.
18. Specify which wireless devices are to communicate with the controller via the repeater
using the keypad connected to the control panel or the DLOADX / ABAX 2 Soft program
(for information on programming, go to the ABAX 2 controller manual).
Due to the specific nature of communication, there can be some delays in the
transmission of information between detectors, repeater and controller in the system.
In order to minimize the delays and speed up the communication, you can set the
detectors permanently in the active state, that is, one in which the detectors will report
each alarm immediately. This applies to the detectors which are violated occasionally
because battery life will not be affected in their case.
4. Specifications
Operating frequency band ...............................
868.0 MHz ÷ 868.6 MHz / 915 MHz – 928 MHz
Radio communication range (in open area)
ACU-220 .............................................................................................. up to 2000 m
ACU-280 .............................................................................................. up to 1600 m
Supply voltage ............................................................................................ 230 VAC, 50-60 Hz