SATEL ACU-280
19
7.1 Controller settings
Fig. 10. DLOADX
program: parameters and options of the controller connected to INTEGRA /
INTEGRA Plus control panel.
Name
– individual name of device (up to 16 characters).
Tamper signaled in partition
[Tamper in part.] – partition where alarm will be triggered in
the event of module tamper.
No auto-reset after three module tamper alarms
[No autorst.3t.] – if this option is enabled,
the feature reducing the number of tamper alarms from the module to three is disabled
(the feature prevents multiple logging of the same events and applies to successive
uncleared alarms).
Communication period
[Response period] – define the time intervals at which wireless
devices are to communicate with the controller. Periodical communication can take place
every 12, 24 or 36 seconds. During periodical communication, the devices inform the
controller about their status, and the controller sends commands to the devices (switches
the detectors into active/passive mode, starts/ends test mode, changes configuration of
the devices, etc.). The communication period has effect on the level of energy
consumption by wireless devices: the less frequent is the communication, the lower is the
energy consumption. For the battery-operated devices it means longer battery life.
Moreover, when the communication takes place less frequently, more wireless devices
can work within each other's operating range.
If you enable the “ECO” option for a wireless device, periodical communication
between that device and the controller will take place every 3 minutes (the
“Communication period” parameter will have no effect on the device operation).
Some information and commands need to be sent immediately. Therefore, additional
communication takes place when the device reports tamper, when the detector reports
alarm, etc.
Higher sensitivity for jamming detection
[High jam sens.] – if this option is enabled, the
sensitivity of detection of radio communication jamming is boosted.