16
Address Point
ID
Description
Options/Range Units
Type
R/W
Notes
+99-128 Reserved
Device Options Setup
46256-46271
+0
Log output
Bit 0 = Dumping to console,
Bit 2 = Server Log
Bit 3 = XP log
Bit 4 = IPLINK log
Bit 5 = Data Server log
Bit 6 = Sharing log
UINT16
R/W
+1
Number of XP faults for reset
0-200
0 – never (50 - default)
+2
Global reset timer (in hours)
0-24
0 – never (24 - default)
+3-15 Reserved
UINT16
R/W
Time/Date Setup
46400-46415
+0
Local time offset, min
0-+/-720
UINT16
R/W
Offset in minutes from UTC
(Universal Coordinated or
Greenwich Mean time)
+1
Daylight savings time (DST) option
0 = DST disabled (standard time
only), 1 = DST enabled
µsec UINT16
R/W
+2
DST start month
1 - 12
UINT16
R/W
+3
DST start week of the month
1 - 4 = 1st, 2nd, 3rd and 4th week,
5 = the last week of the month
UINT16
R/W
+4
DST start weekday
1-7 (1= Sun, 7 = Sat)
UINT16
R/W
+5
DST end month
1 - 12
UINT16
R/W
+6
DST end week of the month
1 - 4 = 1st, 2nd, 3
rd
and 4th week,
5 = the last week of the month
UINT16
R/W
+7
DST end weekday
1-7 (1= Sun, 7 = Sat)
UINT16
R/W
+8
Clock synchronization source
0 = GPS IRIG-B master clock
UINT16
R/W
+9-15 Reserved
UINT16
Clock Setup and Status
46416-46447
+0, 1
Local time, in seconds, since Jan 1, 1970
F1
sec
UINT32
R
+2, 3
Fractional seconds, µsec
µsec
UINT32
R
+4
Fractional seconds, milliseconds 0-999
UINT16
R/W
+5 Seconds
0-59
UINT16
R/W
+6 Minutes
0-59
UINT16
R/W
+7 Hour
0-23
UINT16
R/W
+8
Day of month
1-31
UINT16
R/W
+9 Month
1-12
UINT16
R/W
+10
Year (calendar year minus 2000)
0-99
UINT16
R/W
+11
Weekday
1-7 (Sun = 1, Sat = 7)
UINT16
R
+12
Daylight savings time status
0 = standard time, 1 = daylight
savings time is active
UINT16
R
+13 IRIG-B
status
0,
1 = no signal, 2 = time unlocked,
UINT16
R