2
INSTALLATION – Optional EM Driver and Motion Sensor
STEP 1:
Press the Spring buttons and
remove fixture cover/diffuser.
STEP 4:
Image of the Emergency power
supply installed.
STEP 8:
Remove the nut and washer
of the Motion Sensor.
STEP 11:
Install silicone washer and
secure Motion Sensor stem with lock nut.
STEP 14:
Image below shows
positioning of the Test/Indicator button
and Motion Sensor.
STEP 2:
Use a flat screwdriver to
remove knockouts on the bottom of
fixture housing.
STEP 5:
Remove plastic nut from the
Test/Indicator button.
STEP 9:
Use a flat screwdriver to
remove knockout.
STEP 12:
Image shows positioning
of Motion Sensor.
STEP 15:
Installation of accessories
is compete. Turn power on.
STEP 7:
Connect wire leads from Test/Indicator button
to wire leads from the Emergency power supply.
STEP 3:
Align the Emergency power
supply with the studs on the bottom
housing and secure with supplied nuts.
STEP 6:
Install the Test/Indicator button
through the knockout on the side of the
fixture housing and secure with plastic nut.
STEP 10:
Install Motion Sensor stem
by passing through the knockout on
the side of the fixture housing.
STEP 13:
Connect the wires (see wiring
diagram on page 3). Check wiring is
correct, then put back the cover.
ON
ON
Test/Indicator button
Optional Emergency power supply
Motion Sensor
STEP 16:
While main power is on:
Start Emergency mode test by pressing
the test button for .5 seconds (simulates
the main power outage); Press test
button again for 3 seconds to turn off
the current Emergency mode.
© Copyright 2021 Satco Products, Inc.