12
4.
Float valve:
(See below)
Please note that the float valve is already set by the factory and must NOT be adjusted. It must at all time be
secured vertical to function correctly.
6.3 (f)INCLINATION ANGLE (RANGE OF ANGELS) AT WHICH SYSTEM SHALL BE INSTALLED:
Type of installation on different roofs (using a Satchwell Stand & Cradle designed according to SANS 1307 of
2012):
o
Pitched roof houses (roof pitch around 37°): No back legs required. Only cradle and frame
connected to the trusses as described above, according to SANS specifications.
o
RDP type houses (roof pitch ± 17.5°):The short back legs of the frame enable an inclination of
20° before mounting on an RDP roof of 17.5°, providing a final inclination to horizontal of
around 37°.
o
Flat roofs (roof pitch ± 5°): The long back legs of the frame enable an inclination of 30° before
mounting on an flat roof of 5°, providing a final inclination to horizontal of around 35°.
General :
1.
All holes in walls, ceilings must be made good, as if they had not been made.
2.
All installations must be tidy.
3.
Customer Information and User Manual
4.
The customer / homeowner / user of the system must be supplied with the user manual for the SWH
system, including the telephone numbers for contacting the installer, for ongoing maintenance or
emergencies.
5.
The installer needs to explain to the customer the important and safety aspects operating the system.
Operating range:
From 0.1 to 16 bars
(can resist 20 bars)
Filling flow:
20L/min at 2 bar main pressure