4.6. OPERATIONAL CHECK.
1. Before returning the meter register to normal service, check that it operates properly as follows:
Rotate the input bevel gear and see that the totalizer and individual delivery wheels are driven and
that they record the same amount.. There should be no binding or drag.
2. Rotate the reset gear and see that the shutter drops into place, the wheels aIl reset and that there
is no binding or drag.. At the completion of reset, the zeros should align with the pointer.
3. See Troubleshooting, Table 1. Page 5, if there are any problems.
4.7. IMPORTANT REMARKS
It is disadvised cleaning the whole of counting by using a jet apparatus high pressure,
being able to be the cause of a deterioration of the whole of counting.