Malfunction
Cause
Corrective Action
Spray gun drips
Foreign body
between paint needle
and material nozzle
prevents sealing
Dismantle paint needle
and material nozzle,
clean with cleaning
agent or insert new
nozzle set
Coating material leaks
at the paint needle
(paint needle seal)
Self-adjusting needle
seal defective or lost
Replace paint needle
seal
Sickle-shaped spray
pattern
Horn bore or air circuit
clogged or material
nozzle clogged
Clean thoroughly with a
suitable tool (e.g. noz-
zle cleaning needle)
Faulty spray pattern
Material nozzle
cogged
Clean material nozzle
with nozzle cleaning set
(#30833)
13. Nozzle list
Fluid tip
Technical Data
Nozzle No. Art. No.
Diame-
ter
Angle Width
Material
flow rate
with 70 bar
1840
23044
0,18 mm 40°
18 cm
0.16 Nl/min
2325
7328
0,23 mm 25°
14 cm
0.23 Nl/min
2350
7435
0,23 mm 50°
22 cm
0.23 Nl/min
2360
74922
0,23 mm 60°
24 cm
0.23 Nl/min
2825
16998
0,28 mm 25°
14 cm
0.30 Nl/min
2850
50906
0,28 mm 50°
22 cm
0.30 Nl/min
2865
13771
0,28 mm 65°
25 cm
0.30 Nl/min
3325
20206
0,33 mm 25°
14 cm
0.45 Nl/min
3350
50898
0,33 mm 50°
23 cm
0.45 Nl/min
3365
13789
0,33 mm 65°
28 cm
0.45 Nl/min
3375
74930
0,33 mm 75°
32 cm
0.45 Nl/min
3390
73742
0,33 mm 90°
40 cm
0.45 Nl/min
3825
13797
0,38 mm 25°
15 cm
0.61 Nl/min
3850
7344
0,38 mm 50°
25 cm
0.61 Nl/min