SAFETY INSTRUCTIONS
• Operators must read all instructions prior to operating.
• Power cords must not be placed where heavy equipment can drive over them, nor should they
become a trip hazard for other workers.
• Make certain it is plugged into a properly ground receptacle.
• The unit must be unplugged from the power source before any maintenance work is to be
performed on the unit.
• If the unit should quit working please contact an authorized service technician.
• Do not connect the unit to an improper voltage. This unit use 120 Volt single phase power only.
Product Features
The Bull 240 EBS Vacuum is specifically designed for the concrete floor grinding and polishing industry.
It has strong suction, a two stage filtration system, it has an elongated bag system, it is well constructed,
stable, durable, reliable and it can be easily transported.
Filtration System
The Bull 240 EBS Vacuum filter system consists of one star shaped cartridge pre-filter and two HEPA
secondary filters. When in operation the dust particles enter into the cartridge pre-filter first. The larger
particles will drop down to the bottom the super fine particles will move on through the secondary HEPA
filters. The clean air will discharge from the air outlet and the fine particles will become trapped in the HEPA
filters. With its two stage filtration system it filters dust particles with 99% efficiency down to .03 microns.
FILTRATION SYSTEM
Dusty Air
Clear Air
Clear Air
Dust Collection