User’s manual
16
V.14.a)
Software update
•
Software update should be conducted when the CH boiler is damped.
•
The memory stick which is going to be used to save the set-up file should be empty (prefer-
ably formatted)
•
Make sure that the file saved on the memory stick has exactly the same name as the down-
loaded file so that it is not overwritten.
Insert the memory stick with the software into the controller USB port.
Reset the device by unplugging it and plugging it back in.
When the controller starts again, wait until the software update process starts.
o
Once restarted, the controller display shows the starting screen.
o
Software update starts automatically.
o
During installation process colourful stripes appear on the screen illustrating the installation
progress.
o
Once the installation process is completed, the display shows the main screen.
Once the software update has been completed, you can remove the memory stick from the USB
port.
The software update of ST-66P module may be conducted in a similar way by inserting the memory
stick with the software into the USB port of the additional module.
V.15.
Factory settings
The controller is pre-configured for operation. However, the settings should be customized to the user's
needs. Return to factory settings is possible at any time. When the factory settings option is activated,
all customized settings of the CH boiler (saved in the user's menu) are lost and replaced with the
manufacturer's settings. Then, the parameters may be customized anew.
VI.
Controller functions - Fitter’s menu
Fitter’s menu should be accessed by a qualified person. It is used to configure additional functions of the
controller such as CH boiler parameters, additional valves, additional pumps etc. as well as advanced
settings of basic functions (such as built-in valve parameters).
Block diagram of fitter’s menu is presented below:
Содержание ST-550 zPID
Страница 1: ......
Страница 6: ...User s manual 6...
Страница 7: ...ST 550 zPID 7...
Страница 30: ...User s manual 30...
Страница 36: ...User s manual 36...