background image

MW3520 Installation Guide 

 

Safety and operational notices.

 

1) 

IMPORTANT: 

 When using models fitted with the optional GSM/GPRS radio module, users should carefully 

read the separate leaflet entitled “Special note on GSM/GPRS Safety” before using the product. 

2) 

The MW3520 and MW3410 must only be used with the approved mains power transformer supplied by 
Sarian Systems Ltd. Use with any other power supply may damage the unit and will invalidate the warranty 
and the product approvals. 

3) 

Ports that are capable of connecting to other apparatus are defined as SELV (Safety Extra Low Voltage) 
ports. To ensure conformity with EN60950 ensure that these ports are only connected to ports of the same 
type on other apparatus. 

4) 

The ISDN BRI port is classed as TNV-1 (Telecom Network Voltage – Class 1) and the ADSL / PSTN ports 
are classed as TNV-3 (Telecom Network Voltage – Class 3). To ensure conformity with EN60950 ensure 
that these ports are only connected to ports of the same type. 

5) 

Do not attempt to repair the products. They contain no electronic components that can be serviced or 
replaced by the user. Any attempt to service or repair the unit by the user will void the product warranty. 

6) 

The MW3520 and MW3410 are designed for indoor use only and should be used in an environment that is 
suitable for computers and other electronic equipment.  

7) 

With respect to European EMC requirements, the MW3520 and MW3410 are Class A products. In a 
domestic environment, these products may cause radio interference in which case the user may be 
required to take adequate measures. 

8) 

The GPRS aerial connector is a static sensitive port. Anti-static handling precautions should be taken when 
fitting or removing the aerial from this connector. 

9) 

To comply with ESD requirements this product should be connected to ground using the M3 threaded stud 
at the right hand side of the rear panel. 
 

 

EU Declaration Of Conformity For R&TTE Directive 

We: 

Sarian Systems Limited. 
Beacon House, 
Riverside Business Park, 
Ilkley, 
West Yorkshire, 
LS29 8JZ. 
ENGLAND 

declare under our sole responsibility that the following products: 

Models:  

MW3520,  MW3410 

Part numbers:  81-MW3520-SSEU-00,  
  81-MW3520-SSEU-01 

(GPRS 

option) 

                          81-MW3410-SSEU-00 

conform to the following relevant harmonised standards: 

   

EN60950 (2001) 1

st

 Edition 

(81-MW3520-SSEU-00 and 81-MW3520-SSEU-01) 

  

EN55024: 1998  

 

(81-MW3520 SSEU-00 only) 

  

EN55022: 1998  

 

(81-MW3520 SSEU-00 only) 

 

EN301 511 V7.0.1 (2000-12)  

(81-MW3520-SSEU-01 only) 

 

EN301 489-7 V1.1.1 (2000) (81-MW3520-SSEU-01 

only) 

following the provisions of Council Directive 1999/5/EC on radio equipment and telecommunications terminal 
equipment and the mutual recognition of their conformity. 

Name:   

R C Hudson 

Position: Director 
 
 
Signature: _____________________ 
Date:  

28

th

 October 2004 

on behalf of Sarian Systems Limited. 
 

Содержание MW3520

Страница 1: ... to the contents or use of this manual any software drivers or associated application software provided with this product and specifically disclaims any expressed or implied warranties of merchantability or fitness for any particular purpose Sarian Systems reserve the right to modify or revise all or part of this document its contents and any products described herein at any time without prior not...

Страница 2: ...uitable for computers and other electronic equipment 7 With respect to European EMC requirements the MW3520 and MW3410 are Class A products In a domestic environment these products may cause radio interference in which case the user may be required to take adequate measures 8 The GPRS aerial connector is a static sensitive port Anti static handling precautions should be taken when fitting or remov...

Страница 3: ...n Systems website www sarian co uk Package contents When you have unpacked the unit carefully check the contents These should include MW3520 or MW3410 router hub 230V 13A mains adapter 12V DC output This Installation Guide Sarian 2000 series documentation driver CDROM 1 x 2 metre DSL cable 1 x 2 metre Serial cable 25 way D plug to 9 way D socket 6 x 2 metre CAT5 cable 1 x ISDN 5 x LAN If any item ...

Страница 4: ...luminate green when there is a network connection to the relevant LAN port and flash when data is transmitted received on that port Note that on the MW3410 the LAN 0 indicator is omitted ISDN The operation of this LED depends on how the unit is configured By default it will remain off to indicate that the unit is configured to show the ISDN status on the next 3 LEDs On models fitted with the GPRS ...

Страница 5: ...L DATA Flashes green to show that data is being transferred over the DSL link 1 2 The SIM socket Models fitted with the optional GPRS module also feature a socket at the right hand side of the front panel The GPRS SIM card must be installed in this socket according to the instructions given under the heading Installing the SIM card before the unit may be used to route data over a GPRS network If w...

Страница 6: ...iring straight through cross over Note On the MW3410 this port is not available LAN 1 2 3 4 These RJ45 sockets are the hub ports that may be used to connect to other network devices All four are auto sensing for speed 10 100 BaseT and wiring straight through cross over GPRS On models fitted with the GPRS option this SMA connector is used to attach the dual band GSM stub antenna provided or a suita...

Страница 7: ... separately This may then be plugged into the socket labelled Port 1 to provide a 9 way D serial connector termination You will then need a suitable serial cable to connect this to your terminal Note On the MW3410 and MW3520 models fitted with the GPRS serial Port 1 is not available Step 6 Connecting the LAN cable s Plug one end of one of the supplied 2 metre CAT5 cables into the RJ45 socket label...

Страница 8: ...it is ready to configure This can be done using the built in Web interface or by using the command line interpreter Please refer to the chapter entitled Using the Web Interface or Using The Command Line Interface in the Sarian Systems Web Interface and Command Line Reference Guide as appropriate Note By default PPP 1 is pre configured for ADSL PPP 2 is pre configured for ISDN PPP3 is pre configure...

Отзывы: