background image

 

 

        EC400 / EC450 series Power Control System 

 

E

C

45

0

 

 

 

 

Issue 1 

Page 10 of 13 

12

th

 June 2011 

These warnings will not be repeated unless the water pump power switch is turned off and on again.  
This is to ensure the warning does not become a nuisance. 

3.9  Frost Protection 

On vehicles fitted with water tank frost protection, the control panel frost protect switch can be used to 
turn the feature on or off. 

With protection on, the system monitors the tank water temperature and water level and will control the 
tank heaters accordingly.  If the fresh or waste water levels are less than 25% the appropriate heater 
will be turned off to prevent overheating or damage to the element. 

There are two types of system employed, both working in a very similar way.  One system uses 
heaters with built-in thermostats; the other uses separate temperature probes in the tank.  Both types 
switch on at 4-5C and off at 8-10C 

3.10  Electric Step Operation 

On vehicles fitted with an electric step, this is operated by a button near the entry door.  Press and 
release the button to move the step in or out.  One press of the button will move the step out, a further 
press will move the step in again. 

If the engine is started the step will move in automatically, after a short warning buzzer.  If this 
operation fails due to an obstacle a buzzer will sound continuously to warn that the step is still out, and 
therefore requires your attention. 

3.11  Warnings and Alerts 

If the vehicle engine is started whilst the caravan or motorhome is connected to the 230v supply, a 
warning beep will be heard.  This is to warn you to remove the 230v supply before driving away. 

When the vehicle engine is running both the vehicle battery and the leisure battery LED’s will flash in 
unison to indicate that they are connected together and are being charged by the vehicle. 

Step operation (motorhomes only), if the engine is started with the step in the out position, the step will 
move in automatically, after a short warning buzzer.  If this operation fails due to an obstacle a buzzer 
will sound continuously to warn that the step is still out, and therefore requires your attention. 

Low water level and waste tank, if the fresh water level drops to below 25% a warning beep will be 
heard and the fresh gauge empty LED will flash.  To cancel the warning, press the levels button.  If the 
waste water level rises to full (100%) a warning beep will be heard and the waste gauge full LED will 
flash.  To cancel the warning, press the levels button. 

Low voltage warning and cut off, if the power is turned on and the leisure battery level falls below 9V a 
warning beep will be heard and the leisure battery gauge 10V LED will flash.  To cancel the warning, 
press the levels button.  If the power is turned on and the vehicle battery is selected (being used) and 
the level falls below 10.9V a warning beep will be heard and the vehicle battery gauge 10V LED will 
flash.  To cancel the warning, press the levels button.   

3.12  Common Fault Table 

Fault 

Possible Cause 

Proposed Fix 

Connecting lead between 
the site and Leisure 
Vehicle not connected 

Check and connect lead as per 2.4C 
 

RCD switched off 

Reset RCD as per 2.4D 

RCD not operating 
correctly 

Check supply polarity; if the RCD continues to fail contact your Dealer 
as there is probably an equipment or wiring fault. 

MCB switched off 

Reset MCB by switching OFF (down position) then back ON (up 
position), if the MCB continues to fail contact your Dealer as there is 
probably an equipment or wiring fault. 

No or deficient supply 
from site 

Contact site Warden for assistance 

No 230 volt 

output from PSU 

Other fault 

Contact your Dealer  

Содержание EC400 Series

Страница 1: ...nit also contains the provision for the Radio CD head unit The EC400 EC450 series of power supply units include the EC400 range horizontal units and the EC450 range vertical units further details are contained later in this document The EC400 EC450 series Control Panel CP a remotely located user control panel used to turn circuits on and off and to display battery and water tank information This p...

Страница 2: ...ircuit Breakers MCB Please note that installations with a 3KW Alde heating system will have 2 x 10A and 1x16A MCB s 12V Components Black push switch far left System shutdown switch this switch turns the power control system on or off In is on out is off Yellow push button top right Select button this button is used to scroll through the display items on the LCD screen Red push button bottom right ...

Страница 3: ...ange cable with blue connectors to the Leisure Vehicle and then connect to the mains supply D Check Residual Current Device operation Locate the RCD within the PSU and ensure the RCD is switched on lever in up position Press the Test button and confirm that the RCD turns off lever in down position Switch the RCD back to the on position lever in up position If the test button failed to operate the ...

Страница 4: ...inate when the pump is on and also the level of the water tank will be displayed on the water gauge View Levels To display the battery voltage levels and the water tank levels on the control panel gauges press the levels button The display will remain illuminated for 10 seconds It is possible to lock the display on to allow continuous display This can be achieved by pressing and holding the view l...

Страница 5: ... with the power on press the cabin lights button to turn the main lighting supply on or off Awning Light Button For motorhomes with the power on press the awning light button to turn the awning light on or off Frost Protect Button For motorhomes if when fitted with the power on press the frost protect button to turn on the water tank heating system The adjacent LED will illuminate to show that the...

Страница 6: ...or the three MCB s MCB Rating Output Wire Colour Description 1 10 Amps White 230v Sockets 2 10 Amps White Yellow for heater Extra 230v Sockets Space Heater 2 16 Amps Yellow Alde heating EC470 PSU Only 3 10 Amps Black Blue for water heater Fridge Water Heater 12v Charger internally connected 3 2 Battery Charger The EC400 EC450 system incorporates an intelligent three stage battery charger power con...

Страница 7: ...should be fused at a maximum of 20A B Installation Removal Always disconnect the 230v mains supply and turn the PSU green charger switch to the off position button out before removing or installing the battery When connecting the battery ensure that the correct polarity is observed black is negative and red is positive and that the terminals are securely fastened Crocodile clips must not be used W...

Страница 8: ...permanently connected equipment 3 5 12 Volt DC Fuses WARNING When replacing fuses always replace a fuse with the correct value NEVER replace with a higher value rating as this could damage the wiring harness If a replacement fuse blows do not keep replacing the fuse as you could damage the wiring harness Please investigate the fault and contact your dealer The following table shows the fuse alloca...

Страница 9: ... EC449 468 469 PSU the unit contains an LCD display and two control buttons that allow system information to be viewed or settings changed Press the top yellow select button to change the item being viewed Press the bottom red change button to change the setting Both buttons work on a continuous loop so if you want to return to an item or setting keep pressing the button until the required item is...

Страница 10: ...sure battery LED s will flash in unison to indicate that they are connected together and are being charged by the vehicle Step operation motorhomes only if the engine is started with the step in the out position the step will move in automatically after a short warning buzzer If this operation fails due to an obstacle a buzzer will sound continuously to warn that the step is still out and therefor...

Страница 11: ...ery See 3 4C Engine has been started all equipment has been disconnected to meet EMC requirements See 2 7 Control Panel Problems Control Panel locked erratic function Observe control panel handling instructions Control panel software may have crashed Reboot control panel by turning off the PSU isolate switch Wait 30 seconds then turn the switch back on No 230v supply Check all above Charger not sw...

Страница 12: ...g IP31 Operating temperature Ambient 0 to 35 Centigrade PSU case temperature with full load 65 C Max Automatic shutdown and restart if overheated overloaded Dimensions EC449 EC448 PSU Overall size HxWxD 395 x 205 x 170mm Clearances 75mm above 50mm left right Weight 3 05 Kg EC442 EC447 Control Panel Overall size HxWxD 87 x 250 x 15mm Cut out size HxW 70 x 233mm Fixing centres 130 75mm Weight 114 g ...

Страница 13: ...e C 6000A breaking capacity to BSEN 60898 Electro Magnetic Compatibility EMC directive 2004 108 EC Certificate CE20071224 1 Integrated Charger BS EN 60335 1 2 29 2006 95EC IEC61000 3 2 3 1995 1 Low Voltage Directive 2006 95EC TUV 014900 A1 EN55022 Class B EN55024 Level 2 4 4 Declaration of Conformity Equipment Leisure Power Control System Model name EC440 445 448 449 EC441 442 443 446 447 451 EC46...

Отзывы: