Sargent EC176 Series Скачать руководство пользователя страница 11

 

 

 

             EC176 Power Control System 

 

 

 

 

Issue 1 

Page 11 of 12 

13 July 2018 

Fault 

Possible Cause 

Proposed Fix 

Equipment switched off / 
unplugged 

Check equipment is switched on and connected to the 12v supply. 

PSU overheated / auto 
shutdown operated 

Reduce load on system.  Allow PSU to cool down.  PSU will 
automatically restart when cool. 

Other fault 

Contact your Dealer. 

Pump not 

working 

Fuse blown 

Replace fuse with correct value as per fuse table. 

Pump turned off 

Turn pump on by pressing the pump button at the control panel. 

Setting incorrect 

Both the internal and external pump feeds are controlled from the 
control panel. To alter the setting of the pump switch see your dealer. 
Ensure the setting matches your desired requirement. 

 

4.9  Contact details 

Sargent Electrical Services Limited, provide a technical help line during office hours.  Please contact 
01482 678981 if you require technical help.  For out of hour support please refer to the tech support 
section of the Sargent web site 

www.sargentltd.co.uk

 

5  Technical Data & Approvals 

5.1  Outline specification – EC176PSU & EC361/362 Control Panel 

INPUT 230V 

230 Volts / 0 to 16 Amps 

+ / - 10% 

OUTPUT 230V 

RCD protected, 3 x MCB outputs of 1x16A and 2x10A  
Separate switched channels for combination heater and 
charger 

 

INPUT 12V 

2 x 20A battery inputs via 9 way connector 

 

OUTPUT 12V 

20A total output via multiple switched channels protected 
by 12 fused outputs 

 

Built in  

CHARGER 

Input 220-240 Volts AC +/- 10%, Frequency 50 Hz +/- 6%, 
Current 3A max. 
DC Output 13.8 Volts nominal, Current 12 Amps max (155 
Watts). 

 

Signal INPUT 

4 x Fresh water level (direct to control panel), 1 x Engine 
running, plus multiple vehicle connections  

Fresh water negative sensed 
 

Data IN / OUT 

Data communication to Control Panel via 8 way connector   

IP rating 

IP31 

 

Operating 

temperature 

Ambient 0 to 35° Centigrade 
PSU case temperature with full load 65° C Max 

Automatic shutdown and restart 
if overheated / overloaded 

EC176 

PSU 

Overall size (HxWxD) 260 x 273 x 110mm 
Clearances 75mm above, 20mm below, 50mm left & right 

Fixing centres 262 x 224mm 
Weight 2.2 Kg  

EC361 & EC361 

Control Panel 

Overall size (HxWxD) 95 x 200 x 25mm 
Cut-out size (HxW) 82 x 178mm 

Fixing centres 190mm 
Weight 180 g 

5.2  Approvals 

System: BSEN 1648-1, BSEN1648-2 compliant, BS7671: 2008 compliant 
Residual Current Device: RCD 40A 30mA trip to BS EN 61008 
Miniature Circuit Breakers: MCB’s type C 6000A breaking capacity to BSEN 60898 
Electro Magnetic Compatibility (EMC) directive 89/336/EEC 
Integrated Charger Module: BS EN 60335-1/2.29, 89/336/EEC, IEC61000-3.2/3:1995, EMC certificate 5A121501E  
3rd party tested. 
Low Voltage Directive: 2006/95EC TUV-014900-A1, EN55022, Class B, EN55024/ Level 2 
 

Содержание EC176 Series

Страница 1: ...unsure of any point please contact your dealer distributor for advice before use The system has a number of key components that you will need to be familiar with before attempting to use the system t...

Страница 2: ...ly with the requirements instructions supplied with the generator Please note that some electronic generators may not be compatible with your leisure system Further generator operational information i...

Страница 3: ...supply to the combination water heater central heating system on or off In is ON out is OFF Note the far left 12V DC Shutdown switch is covered in section 2 2 2 4 Operation while driving The EC176 sy...

Страница 4: ...n the pump is on and also the level of the water tank will be displayed on the screen Light button With the power on press the light button to turn a selection of internal lights on Press the button a...

Страница 5: ...control panel 3 3 LED Bar Graph The LED Bar Graph displays the voltage of the selected battery LED Colour Voltage reading 1 Red 9 5 9 LED Flashes 2 Red 9 5 10 9 3 Amber 11 11 4 4 Amber 11 5 11 9 5 Amb...

Страница 6: ...evel is continuously refreshed if the water pump is turned on Pressing the levels button to move to the next screen Water Tank Levels FRESH 50 WASTE 0 4 Select Battery Here you can select which batter...

Страница 7: ...ould be operated each time the vehicle is connected to the mains supply see section 2 3 The Miniature Circuit Breakers MCB s operate in a similar way to traditional fuses and are provided to protect t...

Страница 8: ...position button out before removing or installing the battery When connecting the battery ensure that the correct polarity is observed black is negative and red is positive and that the terminals are...

Страница 9: ...eisure equipment that is controlled by the control panel power switch it will not protect the battery from discharge by permanently connected equipment Leisure battery voltage high With control panel...

Страница 10: ...for assistance Other fault Contact your Dealer Control Panel Problems Control Panel has no display Backlight illumination may have switched off Press the power button or select button to reactivate t...

Страница 11: ...bination heater and charger INPUT 12V 2 x 20A battery inputs via 9 way connector OUTPUT 12V 20A total output via multiple switched channels protected by 12 fused outputs Built in CHARGER Input 220 240...

Страница 12: ...all essential requirements of the Directives Signed Name Position Manufacturer I L Sargent Technical Director Sargent Electrical Services Ltd Unit 39 Tokenspire Business Park Woodmansey Beverley East...