Document 630-881
Revised 09/17/2021
Copyright
©
2021, Sargent & Greenleaf
5/7
Temporarily attach panic bar assembly to interior mounting plate
using (2) #10-32 x 1/2" screws.
Slide panic bar touch pad back into panic bar channel, insert panic bar channel bracket and
filler panel into panic bar channel.
58
Level panic bar assembly.
61
Secure strike with (3)
remaining #10 sheet metal
screws or #10-32 machine
screws, tighten securely. If
machine screws are used,
threadlocker is recom-
mended.
A
4
52
Slide panic bar touch pad partially from panic bar channel.
W
55
F
Adjust trip mechanism to engage
strike. Slowly close door, observe whether
the bolt is released upon closing. If bolt is
not released, use a flat blade screwdriver
and rotate the trip mechanism counter
clockwise 1/2 turn. Repeat adjustment
until bolt is extended upon door closing
and rotate trip mechanism 1 additional full
turn counter clockwise.
Test all door and lock functions for
proper operation. Make necessary
adjustments if required.
53
54
To access High Security Combina-
tion Lock: Unlock center module
and upper module with key,
remove (6) interior module cover
assembly screws and (2) lock
cover screws. Time to preform
this operation is 1 min 10 sec.
Reverse process to re-install
covers. Refer to High Security
Combination Lock - Operating
Instructions for detailed instruc-
tion, including how to change lock
combination.
W
X
Y
Align panic bar assembly to lock assembly.
59
Align panic interface mechanism to panic bar touch pad.
From backside of panic bar touch pad, secure panic
interface mechanism with (2) #8-32 x 3/8" screws.
W
1
W
W
2
W
2
W
1
W
56
57
W
3
W
3
60