background image

 

07-01955E F479-230V/78-006 AU 

Legend Brands, Inc. 

with force. Water may contain chemicals or 
contaminants that can be a health hazard upon contact. 

Airflow shut-off  

The HVE3000 will automatically shut off airflow to the 
blower when the recovery tank is full. This prevents 
water and debris from entering the motor. When the 
recovery tank becomes excessively dirty, or if there is 
too much foam in the tank, the float may not function 
properly. When the blower emits a high-pitched whine 
and there is no vacuum generated, it most likely means 
that the ball float has engaged and that the tank is full 
and needs to be emptied, or that excessive foam is 
present. When this occurs, check the tank and empty it 
if necessary, and use a defoamer any time foam is 
present. 

MAINTENANCE 

WARNING! ELECTRIC SHOCK HAZARD.

 Unplug the 

unit before performing any maintenance. 

Before each use 

Inspect the electrical cord for damage.

 Look for 

fraying, cuts, etc. Do not use the unit if you find any 
damage. Call +1 360-757-7776 to locate the nearest 
service center. 

Check the filter basket and HEPA filter

 (Fig. D).

 

Performance is greatly reduced when either filter is 
clogged. 

 

Check the sump pump float valve 

(Fig. D).

 

Remove 

any clogs or obstructions to the float mechanism.  

Check the manual drain hose 

for clogs or kinks.  

Check all hose fittings. 

Look for cracks, debris, and 

damaged threads or seals.  

Check ball float valve. 

Ensure cover screen is clean. 

After each use 

Clean filter basket and top cover. 

Release cover 

clamps, remove the cover, and lift out basket. Rinse 
basket, basket basin, and cover with water to clean. 
(Clean also as needed during use.) 

Clean recovery tank, float valve, and airflow shutoff 
valve. 

 

1. Release four cover assembly latches and lift off cover 
assembly (see Fig. D). With gravity drain hose directed 
into a suitable drain, remove any accumulated debris 
and wash recovery tank interior with an all-purpose 
detergent. Rinse interior with fresh water. Allow the unit 
to drain completely through the gravity drain hose. 
2. Slide airflow shutoff ball valve assembly downward off 
of the vacuum standpipe (Fig. D

; see also “Remove float 

ball assembly,” p. 6). Rinse valve assembly clean. Make 
sure the float ball moves freely inside the cage and is 
free of any debris. Replace ball valve assembly. 
3. Wipe off pump, float, float arm assembly and tank 
interior with a damp cloth. Allow tank interior and cover 
assembly to dry completely before replacing the cover 
assembly.  

To maintain appearance

, wipe interior and exterior 

surfaces with a damp cloth. For deep cleaning and to 
add a protective shine to the exterior, use Dri-Eaz 
MicroGuard Cleaner and MicroGuard Protectant or a 
similar automotive interior treatment.  

Monthly 

Use an all-purpose silicone spray

 to lubricate wheels, 

castors and latches. Take care to wipe up any excess 
spray, as it may create slippery surfaces. 

As needed 

Replace HEPA filter.

 Replace when the filter is visibly 

dirty. To access the filter, remove the filter cover plate 
thumbscrews and lift off the plate. Replacement filters 
are sold in packs of four. Ask for Dri-Eaz part no. F503 
or Sapphire part no. 20-045. 

Special Maintenance Tasks 

To ensure proper operation, we recommend the 
following maintenance based on hours of use. In 
excessively dusty or dirty conditions, it may be 
necessary to perform these tasks more frequently. 

Blower motor replacement 

800 hrs 

Order the motor brush replacement kit, Dri-Eaz and 
Sapphire part no. S506. Complete instructions are 
provided with the kit.  

 

Pump Inspection and service 800 hrs  
Tools required 

 

10 mm and 3/8 in. nut drivers or sockets with a 6 in. extension and a ratchet. 

 

3/32 in. socket 

 

15/16 in. open end wrench 

 

Short handled screwdriver 

 

Содержание Dri-Eaz HVE3000

Страница 1: ...run appliance over cord Keep cord away from heated surfaces Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or appliance with wet hands Do not put any object into openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce air flow Turn off all controls before unplugging Use extra care when cleaning on stairs Do no...

Страница 2: ...es not fit the outlet have proper outlet installed by a qualified electrician This equipment is for use on a circuit having a nominal rating no more than 230V and is factory equipped with a specific electric cord and plug to permit connection to a proper electric circuit Make sure that the appliance is connected to an outlet having the same configuration as the plug No adaptor should be used with ...

Страница 3: ... as booster Keep capped when not in use Handle Control panel Details in Fig C HEPA exhaust filter grill Thumbscrews allows easy removal for filter replacement FIG B REAR Vacuum inlet from extraction tool Gravity drain hose Keep capped and clipped into place when not in use Grab handle vacuum hose guide Direct hose through guide before use to avoid tipping Filter basket cover Remove by lifting clam...

Страница 4: ...t with a truckmount producing vacuum pressures greater than 12 in H2O 40 6 kPa Doing so could damage the unit and will void the warranty NOTICE Do not operate with water temperatures exceeding 140 F 60 C Doing so could damage the unit and will void the warranty 1 Connect vacuum hose to vacuum inlet 2 Connect power cord 3 Connect pumpout hose to pump outlet and turn pump switch ON For maximum pumpo...

Страница 5: ... assembly see Fig D With gravity drain hose directed into a suitable drain remove any accumulated debris and wash recovery tank interior with an all purpose detergent Rinse interior with fresh water Allow the unit to drain completely through the gravity drain hose 2 Slide airflow shutoff ball valve assembly downward off of the vacuum standpipe Fig D see also Remove float ball assembly p 6 Rinse va...

Страница 6: ...clamp on inside wall of tank with the 15 16 in wrench Cut cable tie and pull out two to three feet of cord or until the cord shows resistance Remove float ball assembly Note It is not necessary to remove the float ball assembly to access the pump However we recommend removing the assembly and cleaning it every time you inspect and clean the pump To remove the float ball assembly loosen lower hose ...

Страница 7: ...ng retaining screw and remove the float ball housing Rinse all components clean and ensure float ball moves freely inside housing Reinstall float ball housing Inspect float assembly Ensure that float moves freely up and down the float shaft Clean as necessary Using the 3 8 in or 10 mm socket remove bolts on both ends of the cross brace Lift off brace ...

Страница 8: ...hose off the outlet Fold up the pump handle and lift out the pump for inspection Rest the pump on a table or other stable surface placed next to the unit There is no need to disconnect the wire harness Pull off the pump intake screen and rinse clean Wipe off any debris from intake area Replace screen ...

Страница 9: ... use SPECIFICATIONS Model HVE3000 High Volume Extractor F479 230V AU Weight 130 lbs 59 kg Dimensions H W D 40 2 22 5 23 6 in 102 1 57 2 59 9 cm Power 230V 6 8A Blower 9 3A Blower Pumpout Tank capacity 12 gal 45 l Maximum performance ratings Blower lift 8 8 in Hg 120 in H2O Pumpout discharge rate 1 in outlet 45 gpm Pumpout discharge rate in outlet 12 gpm Specifications are subject to change without...