Before Installation - Static IP
If you are accessing an Internet NTP server, Port 123
must be open.
If you wish to be able to access the web interface
from a computer that is not on the network, Port
80 must be open.
If you wish your clock to be assigned an IP address
via DHCP, see the previous page.
If the user wants to access the clock by using
the same IP address each time, otherwise known
as a Static IP, then the following steps should
be performed:
1. Use a crossover cable to attach the SBP clock to a
PoE injector, and the injector to your computer.
a. If you are connecting from the clock to the
computer using a PoE switch, the injector is
not needed.
2. If you know the IP address for your clock, enter
it into the address bar of a web browser to
access the clock’s Web Interface.
a. If you do NOT know the IP address for your
clock, power down the clock, then locate
the jumper on the circuit board. Move
the jumper from the SHIPPING POSITION
the CENTER POSITION, as shown in the
diagrams on the right.
b. Power the clock. You should now be able to
access the clock through a web browser at
IP address 192.168.0.123.
3. Access the web interface using the password
6063, then click on the “Network Settings” tab.
4. Confirm that DHCP is set to OFF.
4
3
SHIPPING POSITION
CENTER POSITION