15 16
17 18
85
The Sapling Company, Inc.
1633 Republic Road
Huntingdon Valley, PA 19006
USA
P. (+1) 215.322.6063
F. (+1) 215.322.8498
www.sapling-inc.com
Double Mount Installation - Square Clock - Locally Powered
15)
First remove the gearbox pins
, then attach a
power connector to the ports on the side of
each movement.
17) Slide both clocks back into their housings. You
should hear a snapping noise as the
latches reengage.
16) Loosen the strain relief by unscrewing the two
screws. Slip any excess wiring through them, then
tighten the strain relief by reinserting and tightening
the screws.
18) If you feel the need to detach the clock from the
housing after the installation has been completed,
use a flat-blade screwdriver on the four slots around
the outside of the housing. You may hear a snapping
noise as the internal latches disengage.
WALL
CEILING
1
2