User Manual & Datasheet V 2.1
7
Evaluation Unit (Standard)
7.1
Electrical Specifications
Please refer to Table 1 for Electrical Specifications.
PARAMETER
VALUE
Input Power Supply
18 - 55 V DC and 90 - 265 V AC on same terminal
Output
One set / Two sets of potential free c/o contacts
rated at 5 Amps, 230 V AC for non-inductive loads
Switching Indication
•
Red LED - Alarm
•
Green LED - Normal
•
Yellow LED - System Fault
Power Consumption
5 W
Response Time
1 to 3 seconds
Failsafe Mode
Max. or Min. (Field Selectable)
Time Delay Setting
1 - 25 sec. (For Covered and Uncovered Both)
Table 1: Electrical Specifications
7.2
Mechanical Specifications
Please refer to Table 2 for Mechanical Specifications.
PARAMETER
VALUE
Housing
•
RB : Cast Aluminium weather proof powder
coated paint IP-65
•
SQP : Cast Aluminium weather proof powder
coated paint IP-65 (Square Probe Mounted)
•
FP2A : Cast Aluminium weather & flame proof
powder coated paint suitable for gas group IIA &
IIB as per IS 2148
•
SNSR : Pressure Die Cast Aluminium weather
proof IP-66
Electrical Connector
1/2”, 3/4” BSP / NPT
Cable Gland Type
Single / Double Compression
Operating Temperature
Up to
60
◦
C
Table 2: Mechanical Specifications
Sapcon Instruments Pvt.Ltd.
R
6