– 18 –
Adjustment value determination is effectuated using the "STD
AFPOS" and "FOCUS" values.
If FOCUS=focus1, focus2, focus3, focus4, focus5 and the ad-
justment values fulfill the conditions below, they are determined
as within specifications.
Adjustment value determination
1050<=STD_AFPOS<1240
-40<=focus1<=+40, -50<focus2<+50,
-60<=focus3<=+60, -60<=focus4<=+60,
-150<=focus5<=+150
3. AWB Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination is effectuated using the "AGC",
“CHECK", “CHECK_ND”, "MS", “IRIS”, “IRIS_GAIN” and
“IRIS_OFFSET” values.
If AGC= a1, a2, a3, a4, a5, CHECK= wc0, wc1, wc2,
CHECK_ND= wnc0, wnc1, wnc2, MS= ms1, ms2, ms3, ms4,
IRIS= s1, s2, s3, s4, s5, IRIS_GAIN= g and IRIS_OFFSET=
o the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
100<a1<250, 250<a2<450, 450<a3<600,
550<a4<800, 750<a5<1024
wc0=128
±
2, wc1=128
±
2, wc2=130
±
40
wnc0=128
±
2, wnc1=128
±
2, wnc2=130
±
40
1400<ms1<=2500, 1700<ms2<=2900, 1800<ms3<=3100,
2300<ms4<=3600
100<=s1<=220, 100<=s2<=220, 100<=s3<=220,
100<=s4<=220, 100<=s5<=220
s1>s2>s3>s4>s5
0<=g<=255
0<=o<=255
Adjustment values other than the above are irrelevant.
4. CCD White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
Camera
Pattern box
(color viewer)
DscCalDi
x
OK
Focus Result
STD_AFPOS=1168
FOCUS=-5,-14,-15,-4,-71
ADJ_PZPOS=15
!
Dsc Calibration
x
OK
AWB Result:
1:
AGC=187,356,525,694,863
3F_AGC=1,2
WB=276,516,678
CHECK=128,128,141
WB_ND=275, 515, 691
CHECK_ND=128, 128, 142
IRIS_GAIN: 52
IRIS_OFFSET: 153
MS=1705,2101,2378,2934
IRIS=171,156,137,116,109
0
IRIS=0
Copy