3-7. Adjust Specifications
[CP1 board (Side B)]
Note:
1. Frequency adjustment is necessary to repair in the CP1
board and replace the parts.
Preparation:
1. Remove the cabinet left. You can see VR501 and CL501
in the CP1 board.
2. Insert the SD card.
3. Set the main switch to the REC.
4. Press the power button, and comfirm that the through im-
age from CCD can be seen in the LCD.
1. IC501 Oscillation Frequency Adjustment
Adjustment method:
1. Adjust with VR501 to 496.5
±
1 kHz.
2. Lens Adjustment
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set the camera 0 cm from the collimator. (Do not enter any
light.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens adjustment value will appear on the screen.
6. Click the OK.
Measuring Point
ADJ. Location
Measuring Equipment
CL501
Frequency counter
VR501
Camera
Collimator
COMPL PWB CP-1
(636 091 3738)
IC501
Oscillation
Frequency
Adjustment
Lens
Adjustment
AWB
Adjustment
CCD White
Point Defect
Detect
Adjustment
CCD Black
Point And White
Point Defect
Detect
Adjustment In
Lighted
Factory
Cord
Setting
USB storage
information
registration
Language
Setting
COMPL PWB SY-1
(636 091 3769)
COMPL PWB CA-1
(636 091 3806)
COMPL PWB ST-1
(636 091 3745)
COMPL PWB VF-1
(636 091 3752)
3-6. The adjustment item which in necessary in part exchange
Reset
Setting
COMPL PWB TB-1
(636 091 4025)
LENS ASSY
(645 082 0519)
ADJ. Value
496.5
±
1 kHz
CL501
VR501
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.