3-6. Adjust Specifications
[CP1 board (Side B)]
Note:
1. Frequency adjustment can be carried out in through image
mode.
1. IC501 Oscillation Frequency Adjustment
Adjustment method:
1. Adjust with VR501 to 510.6
±
1 kHz.
2. Lens Data Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “Lens Data” in the LCD “Test”.
3. Type in the value given on the bar code that is attached to
the back of the lens into the blank space next to “PI switch”
in the Lens data dialog box.
The first digit of the bar code value is a “0” or a “1”.
4. Type in the value given on the bar code that is attached to
the surface of the lens into the blank space next to “Delta
SB” in the Lens data dialog box.
However, for lenses that have a blank line instead of a bar
code, type in “202020”.
The first digit of the bar code value is a “2” or a “3”.
5. Click “Set” at the right side of Lens data Dialog box.
3. Lens Adjustment
Preparation:
POWER switch: ON
Adjustment condition:
More than A3 size siemens star chart
Fluorescent light illumination with no flicker
Illumination above the subject should be 400 lux
±
10 %.
Adjustment method:
1. Set the siemens star chart 150 cm
±
3 cm so that it be-
comes center of the screen.
2. Double-click on the DscCalDi.exe.
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
(When adjustment is failed, “NG: X” will display.)
5. Click the OK.
Measuring Point
ADJ. Location
Measuring Equipment
ADJ. Value
CL511
Frequency counter
VR501
510.6
±
1 kHz
CL511
VR501
Camera
Approx.
150 cm 3 cm
Siemens
star chart
DscCalDi
x
OK
Focus Result
NG:
!