– 22 –
3-8. Adjust Specifications
1. Optical Axis Adjustment
Preparation:
POWER switch: ON
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set a distance of 1.0-3.0 cm between the camera lens and
the white part of fluorescent tube viewer.
(Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Input “251” to the “CalMode”, and click the OK.
4. Adjustment value will appear on the screen.
5. Click the OK.
2. Lens Adjustment (Infinity)
3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP1
Factory
Cord
Setting
Language
Setting
COMPL PWB VF1
COMPL PWB ST1
COMPL PWB TB1
Reset
Setting
Lens
Adjust-
ment
(1 m)
AWB
Adjust-
ment
USB
storage
information
registration
CMOS
White Point
Defect
Detect
Adjustment
CMOS Black
Point And
White Point
Defect Detect
Adjustment
In Lighted
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
COMPL PWB TB2
COMPL PWB TB3
Lens
Adjust-
ment
(Infinity)
ASSY, FLEXIBLE PWB CA1
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
Refer to
3-13. Firmware uploading procedure. (Page 26)
Optical
Axis
Adjust-
ment
Camera
Collimator
Camera
1.0~3.0 cm
Fluorescent
tube viewer