– 22 –
3-7. Adjust Specifications
1. Lens Adjustment
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set the camera 0 cm from the collimator. (Do not enter any
light.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens adjustment value will appear on the screen.
6. Click the OK.
Adjustment value determination is effectuated using the "STD
AFPOS", "FOCUS" and “LENS_ERR” values.
If FOCUS=focus1, focus2, focus3, focus4 and the adjustment
values fulfill the conditions below, they are determined as within
specifications.
Adjustment value determination
1800<=STD_AFPOS<=2000
-100<=focus1<=+100, -100<focus2<+100,
-100<=focus3<=+100, -200<=focus4<=+200
lens_error=0
Camera
Collimator
3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP-1
Lens
Adjustment
AWB
Adjustment
CCD White Point
Defect Detect
Adjustment
CCD Black Point
And White Point
Defect Detect
Adjustment In
Lighted
Factory
Cord
Setting
USB storage
information
registration
Language
Setting
COMPL PWB ST-1
COMPL PWB VF-1
Reset
Setting
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
LENS ASSY
ASSY FLEXIBLE PWB CA1
COMPL PWB PW-1
DscCalDi
x
OK
Focus Result
STD_AFPOS=1896
FOCUS=-6,1,-7,73
ADJ_PZPOS=9
LENS_ERR=0
!
Содержание VPC-CA65EXBL
Страница 20: ... 20 2 5 BOARD LOCATION PW1 board CA1 board CP1 board ST1 board VF1 board ...
Страница 27: ...27 MEMO ...
Страница 29: ...29 1 1 2 3 3 4 5 5 6 6 7 7 8 8 9 ACCESSORIES ...
Страница 60: ...July 07 SANYO Electric Co Ltd Osaka Japan Printed in Japan ...