– 22 –
Adjustment value determination is effectuated using the “WB”,
“CHECK", “WB_ND”, “CHECK_ND”, "MS", “MS_M”, “MS_C”,
“MS_C2”, “IRIS_PWM1”, “IRIS_PWM2”, “IRIS_PWM3”,
“IRIS_PWM4” “IRIS_PWM5” and “IR_TEMP_AD” values. If
WB = w1, w2, w3
CHECK = wc0, wc1, wc2
WB_ND = wn1, wn2, wn3
CHECK_ND = wnc0, wnc1, wnc2
MS = ms1, ms2
MS_M = ms3, ms4
MS_C = ms5, ms6
MS_C2 = ms7, ms8
IRIS_PWM1 = s1, s2
IRIS_PWM2 = s3, s4
IRIS_PWM3 = s5, s6
IRIS_PWM4 = s7, s8
IRIS_PWM5 = s9, s10
IR_TEMP_AD = itad
the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
wc0=128
±
2, wc1=128
±
2, wc2=130
±
40
wnc0=128
±
2, wnc1=128
±
2, wnc2=130
±
40
223<w1<335, 418<w3<626
223<wn1<335, 418<wn3<626
1200<=ms1<=4450, 240<=ms2<=2240,
980<=ms3<=2980, 820<=ms4<=2820,
700<=ms5<=2700, 570<=ms6<=2570,
470<=ms7<=2470, 360<=ms8<=2360
0<=s1<=255, 0<=s2<=255, 0<=s3<=255, 0<=s4<=255,
0<=s5<=255, 0<=s6<=255, 0<=s7<=255, 0<=s8<=255,
0<=s9<=255, 0<=s10<=255
s1>s2>s3>s4>s5>s6>s7>s8>s9>s10
250<=itad<=893
Adjustment values other than the above are irrelevant.
4. CMOS White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
3. AWB Adjustment
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100
±
20 (K)
Luminance: 900
±
20 (cd/m
2
)
Adjusting method:
1. Set a distance of 0.5-1.0 cm between the pattern box and
the camera. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Camera
Pattern box
(color viewer)
Dsc Calibration
x
OK
AWB Results:
1:
WB=287,537,550
CHECK=128,127,133
WB_ND=286,536,536
CHECK_ND=127,128,133
IR_TEMP_AD=419
IRIS_PWM1=215,190
IRIS_PWM2=176,172
IRIS_PWM3=158,150
IRIS_PWM4=146,138
IRIS_PWM5=123,109
MS=2402,1395
MS_M=1911,1745
MS_C=1684,1535
MS_C2=1470,1458
Fno_FOR_ISO=-1
SS_FOR_ISO=-1
YLELEL_FOR_ISO=-1
Copy
When all of the AWB adjustment screen
is not displayed, use a scroll bar.