OPTION SETTING
4
POLARITY setting
Use the cursor button (
j
or
l
) to move the cursor to
POLARITY, then use the cursor button (
d
or
c
) to select
“NO” or “NC”.
Available settings:
•
NO:
Normal open (Normally open so closed condition is
detected as input.)
•
NC:
Normal closed (Normally closed so open condition is
detected as input.)
5
Motion sensor input setting (MOTION)
Use the cursor button (
j
or
l
) to move the cursor to
MOTION, then use the cursor button (
d
or
c
) to select
the input.
Matches information from the camera’s motion sensor and
the external alarm and outputs it.
Available settings:
•
OFF:
Does not output a motion sensor alarm.
•
AND:
Outputs an alarm when an external alarm input and
motion sensor alarm are detected at the same time.
1
External alarm input
2
Motion sensor detection
•
OR:
Outputs an alarm if either an external alarm or a
motion sensor alarm is detected.
6
Alarm duration setting (DURATION)
Use the cursor button (
j
or
l
) to move the cursor to
DURATION, then use the cursor button (
d
or
c
) to
select the alarm duration.
Set the duration for the following alarm input reception.
Available settings:
5S (default setting), 10S, 15S, 20S, 30S,
1M, 2M, 3M, 4M, 5M
☞
To close the menu screen or return to the previous
screen, select BACK or END for MENU and press the SET
button.
3, 4
ALARM SETTING
ALARM IN ALM
POLARITY NO
MOTION OFF
DURATION 5S
ALARM OUT OFF
POLARITY NO
ALARM TIME 5S
LINE OUT OFF
1
DURATION
ALARM OUT
ALARM TIME
2
L5AD2/XE (VCC-ZM400P) GB 2003, 1, 31
Eng
lish
58