– 5 –
Connections and Settings
Make sure to also consult the Power Board Unit Instruction Manual.
L
N
G
A
WH
B
L
S
L
O
R
B
R
B
K
Y
L
R
D
G
R
L
L
485A
485B
1
2
1
System control setting switches
• Switch 6 is unused.
• The factory setting is represented in bold.
1
Baud rate
Set the same baud rate as that on the camera.
2
Control method
Set either to RS485 or coaxial (COAX).
3
Protocol
Set the protocol for controlling the camera.
4
Termination (Switch 5)
“OFF” is set by default.
When connecting multiple cameras, termination setting must be “ON”
on the last camera while it must be “OFF” on all others.
2
Address setting switches
Set the camera address.
See “Address Settings Table” on page 7.
Switch
1
2
2400
OFF OFF
4800
OFF
ON
9600
ON
OFF
19200
ON
ON
Switch
3
Coaxial (COAX)
ON
RS485
OFF
Switch
4
SSP (SANYO)
OFF
PELCO
ON
1
2
3
4
5
6
ON
1 234
1
2
3
4
5
6
7
8
ON
Power Supply Connection
For the connections use cables higher than
18 AWG.
AC 24 V
or
AC 230 V
• Fix the power cable end firmly so that the power
terminal connection does not come loose. Use
solderless terminals (ring or spade type) for wiring.
• After connection, always install the supplied power
terminal cover
A
for safety reasons.
<Ground>
<Neutral>
<Live>
Monitor Connection
Supported coaxial cables
• Using different cables from those specified here may attenuate the
video and/or sync signals and interfere with correct transmission.
• RG-59U coaxial cables can be used when distance between
devices is short, but not in duct or aerial routing.
Cable type
Length
RG-59U (3C-2V)
250 m (273.4 yd) max.
RG-6U (5C-2V)
500 m (546.8 yd) max.
RG-11U (7C-2V)
600 m (656.2 yd) max.
BNC type
Connections
SIDE-A
Switch
Settings
SIDE-B
1
Controller connection
White
Yellow
2
Alarm signal input
3
Alarm signal output
If a lamp is connected to this cable, it will light up
when an alarm signal is received or when the
built-in motion sensor detects movement.
For details on
2
and
3
, refer to the “Alarm Settings (ALARM)” in
the Instruction Manual.
CAMERA
LENS
PAN/TILT
AUTO MODE
ALARM
PRIVACY MASK
PASSWORD
LANGUAGE
OPTION
PRESET
MENU
ALARM
ALARM IN
ALARM OUT
ALARM DISABLE
MOTION
ALARM DISPLAY
PRESET
MENU
SET
SET
SET
SET
SET
SET
SET
SET
SET
OFF
BACK
1
1
OFF
OFF
OFF
OFF
BACK
y
y
IN 1 - 8
To COM
OUT 1/2
To COM
Alarm input
signal
Alarm output
signal
Joint board
All connection cables should be 24 AWG or higher with a
maximum length of no more than 600 m.
Do not connect the power cord until all other
connections have been completed.