– 5 –

Connections and Settings

Make sure to also consult the Power Board Unit Instruction Manual.

L

N

G

A

WH

B

L

S

L

O

R

B

R

B

K

Y

L

R

D

G

R

L

L

485A
485B

1

2

1

System control setting switches

• Switch 6 is unused.

• The factory setting is represented in bold.

1

Baud rate

Set the same baud rate as that on the camera.

2

Control method

Set either to RS485 or coaxial (COAX).

3

Protocol

Set the protocol for controlling the camera.

4

Termination (Switch 5)

“OFF” is set by default.
When connecting multiple cameras, termination setting must be “ON” 
on the last camera while it must be “OFF” on all others.

2

Address setting switches

Set the camera address.
See “Address Settings Table” on page 7.

Switch

1

2

2400

OFF OFF

4800

OFF

ON

9600

ON

OFF

19200

ON

ON

Switch

3

Coaxial (COAX)

ON

RS485

OFF

Switch

4

SSP (SANYO)

OFF

PELCO

ON

1

2

3

4

5

6

ON

1 234

1

2

3

4

5

6

7

8

ON

Power Supply Connection

For the connections use cables higher than 
18 AWG.

AC 24 V

or

AC 230 V

• Fix the power cable end firmly so that the power 

terminal connection does not come loose. Use 
solderless terminals (ring or spade type) for wiring.

• After connection, always install the supplied power 

terminal cover 

A

 for safety reasons.

<Ground>

<Neutral>

<Live>

Monitor Connection

Supported coaxial cables

• Using different cables from those specified here may attenuate the 

video and/or sync signals and interfere with correct transmission.

• RG-59U coaxial cables can be used when distance between 

devices is short, but not in duct or aerial routing.

Cable type

Length

RG-59U (3C-2V)

250 m (273.4 yd) max.

RG-6U (5C-2V)

500 m (546.8 yd) max.

RG-11U (7C-2V)

600 m (656.2 yd) max.

BNC type

Connections

SIDE-A

 Switch 

Settings

SIDE-B

1

 Controller connection

White

Yellow

2

Alarm signal input

3

Alarm signal output

If a lamp is connected to this cable, it will light up 
when an alarm signal is received or when the 
built-in motion sensor detects movement. 

For details on 

2

 and 

3

, refer to the “Alarm Settings (ALARM)” in 

the Instruction Manual.

 CAMERA
 LENS
 PAN/TILT
 AUTO MODE
 ALARM
 PRIVACY MASK
 PASSWORD
 LANGUAGE
 OPTION

 PRESET
 MENU

        ALARM
 
 ALARM IN
 ALARM OUT
 ALARM DISABLE

 MOTION
 ALARM DISPLAY

 PRESET
 MENU

SET
SET
SET
SET
SET
SET
SET
SET
SET

OFF
BACK

1
1
OFF

OFF
OFF

OFF
BACK

y

y

IN 1 - 8

To COM

OUT 1/2

To COM

Alarm input 
signal

Alarm output 
signal

Joint board

All connection cables should be 24 AWG or higher with a 
maximum length of no more than 600 m.

Do not connect the power cord until all other 
connections have been completed.

L5BU2_XE(INSTALLATION).book  5 ページ  2006年12月8日 金曜日 午後3時55分

Содержание VCC-9500P

Страница 1: ...ount Closed Type 3 In ceiling Mount Open Type 4 Connections and Settings 5 Address Settings Table 7 Pattern Sheet inserted at the end of this manual CAUTION For VA 80S Power Borard Unit ALL POLE MAINS SWITCH with a contact separation of at least 3mm in each pole shall be incorporated in the electrical installation of the building Important Be careful when opening holes for installing the unit Work...

Страница 2: ...ion manuals Power Board Unit VA 84S for AC24V VA 80S for AC230V Camera unit Indoor Type Outdoor Type In ceiling Mount Surface Mount P3 P4 P2 In ceiling Bracket Closed Type VA 80ME In ceiling Bracket Open Type VA 80MF Pendant Mounting Bracket VA 80BP Wall Mounting Bracket VA 80BW Corner Mounting Adapter VA 80AC Pole Mounting Adapter VA 80AP Attachment VA 80A Outdoor Housing VA 80EX Surface Cover VA...

Страница 3: ...lor blue on the camera unit and the power board unit and push the camera unit until they click 9 Align the arrows H of the same color blue on the inner side of the surface cover and the power board unit and fix the cover by rotating it clockwise How to attach the drop prevention cable accessory 1 Peel off the two sided tape K at the end of the cable and attach it to the hook L on the inner side of...

Страница 4: ...bracket top hook F 6 Connect the video cable and pass the connection cables through the bracket 7 Insert the bracket into the ceiling hole and fix it using screws G 2 places 8 Connect the cables and set the switches See Connections and Settings on page 5 9 Align the arrows C of the same color blue on the camera unit and the inner side of the bracket and push the camera unit until they click F Alig...

Страница 5: ...ss the connection cables through the bracket 7 Insert the bracket into the ceiling hole and fix it using screws E 2 places 8 Connect the cables and set the switches See Connections and Settings on page 5 9 Align the blue sticker F on the bracket and the arrow F of the same color on the camera unit and then push the camera unit until they click F Align the SANYO logos on the supplied bracket cover ...

Страница 6: ...ver A for safety reasons Ground Neutral Live Monitor Connection Supported coaxial cables Using different cables from those specified here may attenuate the video and or sync signals and interfere with correct transmission RG 59U coaxial cables can be used when distance between devices is short but not in duct or aerial routing Cable type Length RG 59U 3C 2V 250 m 273 4 yd max RG 6U 5C 2V 500 m 546...

Страница 7: ...m input output cables Video cable A RS 485 B DO NOT CONNECT TO PHONE LINE 1 IN OUT MONITOR OUT MON2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MAIN VIDEO A B TELEMETRY 1 16 Video input terminal Camera Camera Video input terminal Monitor sold separately Video input terminal Terminator switch Communication conversion connectors System controller sold separately Digital video recorder sold separately L5BU2...

Страница 8: ...88 m m m m 61 189 m m m m m 62 190 m m m m m 63 191 m m m m m m 64 192 m 65 193 m m 66 194 m m 67 195 m m m 68 196 m m 69 197 m m m 70 198 m m m 71 199 m m m m 72 200 m m 73 201 m m m 74 202 m m m 75 203 m m m m 76 204 m m m 77 205 m m m m 78 206 m m m m 79 207 m m m m m 80 208 m m 81 209 m m m 82 210 m m m 83 211 m m m m 84 212 m m m 85 213 m m m m Address Camera No Switch No Protocol SANYO PELCO...

Страница 9: ...Pattern Sheet mm inch 186 7 3 166 6 5 4 φ4 5 0 2 P D φ168 6 6 Scale 1 1 L5BU2_XE INSTALLATION book 0 ページ 2006年12月8日 金曜日 午後3時55分 ...

Страница 10: ...ier recyclé Impreso en papel reciclado Gedruckt auf Recyclingpapier 使用再生纸印刷 1AC6P1P3149 L5BU2 XE 1206KP SY SANYO Electric Co Ltd Printed in Japan b Dimensions mm inch 156 6 1 71 2 8 φ136 5 4 L5BU2_XE INSTALLATION book 1 ページ 2006年12月8日 金曜日 午後3時55分 ...

Отзывы: