BASIC OPERATION
Connect the camera to the power unit and to the system controller (sold separately), then use the system controller to operate the
camera. This section principally gives instructions concerning the camera and the power unit.
1
Make all the connections.
Turn off the power to all the devices.
2
Remove the camera cover.
Remove the cover attaching screw, then remove the cover.
3
Termination setting
Camera: The termination is set using DIP switch No. 1 of
switch SW1 on the external sync control panel. Set
the termination to ON for the last unit only,
termination on all other units must be set to OFF.
Power unit: The termination is set using DIP switch No. 8 of
the RS-485 ADDRESS switch on the power unit.
System controller: The termination is set using the
TERMINATE DIP switch on the system
controller rear panel.
4
Data transmission speed setting
Camera: Set the data transmission speed using DIP
switches No. 1 and 2 of switch SW3 on the external
sync control circuit board. The default setting is
19200 bps.
Power unit: Set the data transmission speed using DIP
switches No. 1 and 2 of the RS-485 BAUD
RATE switch on the power unit.
System controller: Set the data transmission speed in
BAUD RATE SET on the menu screen.
Note: Make sure all connected devices transmission speed
settings are the same.
5
Address setting
Camera: Set the address using switches SW1 and SW2 of
the control circuit board. The address default
setting is “01”.
Power unit: Set the address using switches DIP switches
No. 1 to 7 of the RS-485 ADDRESS switch.
System controller: Set the address using the ADDRESS
DIP switches on the system controller
rear panel.
Note:
•
Address settings are from 1 to 127. See the tables on
pages 11 and 12, for details on setting the addresses for
the camera and the power unit.
•
Make sure the address of the power unit is the same as
the one for the corresponding camera.
6
Tighten the cover attaching screw to install the cover,
then turn all the devices on.
7
Operation using the system controller
The following two operating modes are available. For detailed
instructions, please refer to the system controller instruction
manual.
Direct operation using the Camera command
(CAMERA) buttons on the system controller
This method allows you to set the backlight correction, the
electronic shutter function, etc., to adjust the image
according to the conditions when filming by adjusting the
camera basic settings.
Operation using the FUNCTION button to call-up
commands, and selecting a command from the six
types of commands available
This method allows you to use the special functions of the
camera, such as the auto vertical and horizontal
movement function, and to memorise camera angles that
can then be used with the auto-pan or the sequential pan
functions.
(Call-up commands)
•
ALARM OUT
•
AUTO PAN
•
SEQUENCE
•
PRESET MEMORY
•
L-L PAHSE
•
RESET
Camera command
(CAMERA) buttons
Numeric keypad buttons
FUNCTION button
L53Y4/XE (VCC-9250P GB) 2000. 11. 28
8