background image

PRECAUTIONS

In case of problem

Do not use the camera if smoke or a strange odour comes from the
unit, or if it seems not to function correctly. Disconnect the power
cord immediately, and consult your dealer (or a Sanyo Authorized
Service Centre).

Do not open or modify

Do not open the cabinet, as it may be dangerous and cause damage
to the unit. For internal settings and repairs, consult your dealer (or a
Sanyo Authorized Service Centre).

Do not put objects inside the unit

Make sure that no metal objects or flammable substance get inside
the camera. If used with a foreign object inside, it could cause a fire,
short-circuits or damages.

If water or a liquid gets inside the camera, disconnect the power cord
immediately, and consult your dealer (or a Sanyo Authorized Service
Centre). Be careful to protect the camera from rain, sea water, etc.

Be careful when handling the unit

To prevent damages, do not drop the camera or subject it to strong
shock or vibration.

Install away from electric or magnetic fields

If installed close to a TV, radio transmitter, magnet, electric motor,
transformer, audio speakers the magnetic field they generate will
distort the image.

Protect from humidity and dust

To prevent damages to the camera, do not install it where there is
greasy smoke or steam, where the dampness may get too high, or
where there is a lot of dust.

Protect from high temperatures

Do not install close to stoves, or other heat generating devices, such
as spotlights, etc., or where it could be subject to direct sunlight, as
that could cause deformation, discoloration or other damages.

Be careful when installing close to the ceiling, in a kitchen or boiler
room, as the temperature may raise to high levels.

Install where the temperature range will stay between –10° C and
50° C. (no condensation)

Cleaning

Dirt can be removed from the cabinet by wiping it with a soft
cloth. To remove stains, wipe with a soft cloth moistened with a
soft detergent solution and wrung dry, then wipe dry with dry soft
cloth.

Do not use benzine, thinner or other chemical product on the
cabinet, as that may cause deformation and paint peeling.
Before using a chemical cloth, make sure to read all
accompanying instructions. Make sure that no plastic or rubber
material comes in contact with the cabinet for a long period of
time, as that may cause damage or paint peeling.

EN
G

L

IS

H

English

Содержание VCC-6580

Страница 1: ...refully Be sure to keep it handy for later reference Über diese Bedienungsanleitung Lesen Sie bitte vor der Montage und dem Inbetriebnehmen der Kamera zuerst diese Bedienungsanleitung sorgfältig durch und bewahren Sie sie zum späteren Nachschlagen auf A propos de ce manuel Avant d installer et d utiliser la caméra veuillez lire ce manuel attentivement Gardez le à portée de main pour toute référenc...

Страница 2: ...0 000 picture elements Equipped with a DSP Digital Signal Processor function Horizontal resolution more than 520 TV lines Minimum required illumination of 0 5 lx F1 2 lens Backlight compensation Multi spot metering normal and high and center weighted metering Low smear anti blooming low lag no burning and no geometric distortion using the CCD solid state image device 100 solid state components giv...

Страница 3: ...nsformer audio speakers the magnetic field they generate will distort the image Protect from humidity and dust To prevent damages to the camera do not install it where there is greasy smoke or steam where the dampness may get too high or where there is a lot of dust Protect from high temperatures Do not install close to stoves or other heat generating devices such as spotlights etc or where it cou...

Страница 4: ...Line phase adjustment volume LINE PHASE When using two cameras or more the image on the monitor may roll vertically when switching sources This rolling can be minimized by turning this volume 5 Lens iris output connector LENS This 4 pin connector is used to send the DC control signal and power supply to an auto iris type lens 6 Camera setup section under the cover To access the controls remove the...

Страница 5: ...stallation bracket The bracket can be fixed at the top or bottom of the camera When fixing the bracket be sure to use the longer screws and install the shorter screws on the opposite side to seal the openings CAUTION When installing the camera support select a location that can support the total weight of the camera and accessories 1 Shorter screws M3 x 4 2 Longer screws M3 x 6 3 Camera mounting s...

Страница 6: ...a opening then turn the lens slowly to install it C mount type lens To allow for flange back adjustment install the C mount adaptor option on the lens mount then carefully align the lens mount with the camera opening and turn the lens slowly to install it 3 Connect the lens plug to the lens iris output connector LENS on the side of the camera Depending on the type of lens the shape of the lens plu...

Страница 7: ...oto position adjust the flange back position as described below 1 Loosen the FLANGE BACK LOCK screw 2 Set to the maximum telephoto position and focus the picture using the focus ring 3 Set to the maximum wide angle position and focus the picture using the FLANGE BACK ADJ screw Repeat steps 2 and 3 if the image does not stay in focus when changing from a wide angle shot to a telephoto shot 4 When t...

Страница 8: ... cord into a wall outlet The POWER indicator A will light Adjust the picture on the monitor using the Brightness and Contrast controls etc Coaxial cable type and maximum length Cable type RG 59U 3C 2V 250 m maximum Cable type RG 6U 5C 2V 500 m maximum Cable type RG 11U 7C 2V 600 m maximum CAUTION The RG 59U type cable should not be run through electrical conduits or through the air Using CCTV Vide...

Страница 9: ...ol GAIN High HI Normal NOR NOR 4 Aperture compensation setting AP Sharp SHR Normal NOR NOR 5 Backlight compensation setting BLC Multi M Center C OFF 6 White balance switch WB Auto Tracing White Balance ATW Manual MWB ATW Colour RED or BLUE adjustment volume adjustable 7 External sync setting SYNC Line Lock LL Internal sync INT INT 10 9 8 7 6 5 4 3 2 1 MSB 1 2 3 EI HI M C SHR MWB VR302 VR303 VR301 ...

Страница 10: ...00 7 1 4000 8 1 10000 Unit sec Iris function setting Change iris setting when using either lens below EI for indoor use When using a manual or fixed iris lens and the electronic iris function is on Set the lens aperture to the shortest F stop AI When using an auto iris lens If the entire image is too dark or too bright adjust the contrast using the LEVEL dial L Counterclockwise Closes the lens iri...

Страница 11: ...camera has three different backlight compensation modes Change the mode to match the backlight condition Multi spot metering normal mode When applying backlight compensation to the entire screen Multi spot metering high mode When applying more backlight compensation than normal mode Center weighted metering mode When applying backlight compensation to only the central portion of the screen OFF Fac...

Страница 12: ...ratio and or BLUE VR303 to set the blue ratio Sync setting LL Line Lock Synchronizes the unit with power frequency when two or more cameras are connected via a switcher unit When the image on the monitor rolls vertically adjust the phase If using this unit as the second or subsequent camera Adjust the roll by turning the LINE PHASE dial If using this unit as the first camera Adjust the roll using ...

Страница 13: ...orrectly set The picture is not clear Is the monitor correctly adjusted Is the flange back position correctly set Is the lens focus correctly adjusted Are the lens surfaces clean If there is dust or finger prints on the lens the image quality will deteriorate To clean the lens use a soft cloth or a commercially available lens cleaning set SERVICE This camera is a precision instruments and if treat...

Страница 14: ...lens Backlight compensation OFF Multi spot metering 2 modes Center weighted metering Iris function Manual EI AI switching Electronic iris range 1 0 lx to 50 000 lx F 1 2 lens GAIN NOR Electronic shutter 8 speeds selectable by switches 1 50 1 120 1 250 1 500 1 1000 1 2000 1 4000 1 10000 s Flange back 12 5 mm 0 5 mm White balance ATW Manual switching Gain control Normal High switching Aperture Sharp...

Отзывы: