PARTS NAMES AND FUNCTIONS
1
Hood lens
2
Focus ring
The focus does not need adjustment for subjects 1 m and more
from the lens. If the subject is closer than 1 m, turn the focus ring
to adjust the focus as necessary. (See page
9
.)
3
Lens
4
Lens cover
This cover will protect the lens from dust and damage.
5
24 V AC input terminal
(24 V AC, GND)
With this camera use only the 24 V AC
power adaptor model No.
VPT-115
available from Sanyo.
Power supply connections
Use a 3 wire grounded cable (22 AWG
or more), and connect as shown by the
illustration.
CAUTION:
• To prevent camera and/or AC adaptor
failure, pay close attention polarity
when making the connections.
• To prevent fire hazard any UL listed
wire rated VW-1, should be used for
the 24 V AC cable input terminal.
1
2
3
4
5
6
7
8
9
8
F
GND
AC
AC
L73E4/US GB 1998, 20, 15
4
English