9. Storage Condition 

9-1 Storage Temperature and Humidity(less than 3 months) 

  Store  the  cell  at  temperature  range  -20~+35

,  low  humidity(less  than  70%RH)  and  no 

corrosive gas atmosphere. 

  No condensation on the cell 

9-2 Long Period Storage 

  In  case  of  long  period  storage,  store  the  cell  at  temperature  range  -20~+20

,  low 

humidity(less than 70%RH), no corrosive gas atmosphere. 
And  in  this  case,  charge  condition  of  the  cell  is  SANYO  shipment  charge  state  or 
discharge state. 

  No condensation on the cell. 

 

10. Precautions on Handling Lithium Ion Cells 

In term of shipping and assembling the battery pack, this chapter describes precautions on 
handling SANYO lithium ion cells, which are assembled for PDA’s battery packs by Nexcon 
Technology Co., Ltd.. This battery pack consists of UF103450P. 

10-1 Expiration Date 

 

Assemble single cell into battery pack within 1 month after delivery. 

10-2 Precautions on Series Connection of Cell 

  When the cells are connected in series, use same lot number, same shipping charge date 

and same capacity rank cells, and use within 20mV voltage difference. 

 

Lot  number,  shipping  charge  date  and  capacity  rank  are  on  carton  label  when  SANYO 
shipping for series. 

When the cells are connected in series, the discharge end voltage should be 3.0V/cell. 

 

10-3 Precautions on Terminals of Cell 

  Do not over-stress or rotate at positive terminal plate and negative cap. 

By over-stress, it has possibility to remove the welding point and cause leakage or short 
circuit. 

10-4 Inspection before Shipment of the Battery Pack 

  About  all  battery  pack,  inspect  voltage,  internal  impedance  and  function  of  protection 

circuit before shipment. 

10-5 Packing and Shipping Cells 

  When  cells  are  re-shipped  to  assembling  factory,  make  enough  attention  the  packing  to 

avoid stress by shipping. 
SANYO recommends the same package shipped from SANYO when re-shipping. 
Even  if  after  open  package,  when  re-shipping,  use  the  same  parts  and  materials  from 
SANYO for re-packing. 

10-6 Abnormal Cell 

  Do not use abnormal cell which has damages by shipping stress, drop, short or something 

else, and which gives off electrolyte odor. 

 
 

File  No 

UF103450-849 

Energy Company, SANYO Electric Co., Ltd. 

Portable Rechargeable Battery Business Group 

Lithium-Ion  Battery  Business  Unit 

Содержание UF103450P-NETE-5

Страница 1: ......

Страница 2: ......

Страница 3: ...0 40 3 9 Internal Resistance less than 100mΩ AC Impedance 1kHz 3 10 Weight less than 39 8g 3 11 Operating Temperature Charge 0 40 Discharge 20 60 3 12 Surroundings Temperature Range for Shipped Battery less than 1month 20 50 less than 3months 20 40 Percentage of recoverable capacity 80 2 less than 1year 20 20 1 Maximum discharge current as a single cell state is as above stated However after assem...

Страница 4: ...ged at CC CV 1 88A 4 20V for 3 0hours discharged at 1 88A to 2 75V end voltage After 500cycles discharging time is measured as specified in paragraph 4 2 32min or more 4 4 Temperature Within 1hour after fully charged at 25 the cell is stored at 0 for 3hours Discharge time is measured as specified in paragraph 4 2 at 0 30min or more Within 1hour after fully charged at 25 the cell is stored at 60 fo...

Страница 5: ...ne delivered a week before at most The test shall be performed at 25 2 Standard temperature of second grade adopted in JIS Z 8703 Standard Test Conditions 65 20 Standard humidity of twentieth grade adopted in JIS Z 8703 Standard Test Conditions The grade of voltmeter and ammeter used in the test shall be higher than class 0 5 adopted in JIS C 1102 Electric Indicator 5 Design Construction A cell sh...

Страница 6: ...ould be 0 40 Discharge Discharge current must be below 2 00A cell Discharge temperature range should be 20 60 Discharge end voltage must be over 2 75V cell Over Discharge Do not over discharge a battery below 2 0V cell Battery position in PDA and charger To avoid degradation of battery performance by heat a battery should set the place apart from heat generating electronic parts inside PDA and cha...

Страница 7: ...the cell voltage or the voltage of cell block will be over 4 25V However in case that the charge system can control the cell voltage or the voltage of cell block within 4 25V the overcharge protection can be controlled near 4 25V Over discharge protection At the voltage range 2 20 2 40V cell over discharge protection should work Then discharge current shall be shut down and consumption current is ...

Страница 8: ...pping charge date and same capacity rank cells and use within 20mV voltage difference Lot number shipping charge date and capacity rank are on carton label when SANYO shipping for series When the cells are connected in series the discharge end voltage should be 3 0V cell 10 3 Precautions on Terminals of Cell Do not over stress or rotate at positive terminal plate and negative cap By over stress it...

Страница 9: ...If the cell voltage drops to 0V as a result of storage and the cell is charged at this condition the FET on the protection circuit may generate heat The charger must have the pre charge system Pre charge current of charger should be approximately 0 18A When the battery voltage becomes 3 0V cell standard charge should be started When the battery voltage is less than 3 0V cell even after the set per...

Страница 10: ...in individual cells and then it causes the generating heat smoke rupture or flame In addition do not use the battery under the heated place more than 80 for same reason 3 Charger and Charge Condition Do use the specified charger and observe charging requirement If the battery is charged with unspecified condition under high temperature over the regulated value excessive high voltage or current ove...

Страница 11: ...cuit in the battery is broken the battery will be charged at abnormal voltage or current and abnormal chemical reaction might occur It might cause leakage heat smoke rupture and or fire 10 Penetration Do not drive a nail into the battery strike it by hammer or tread it As the battery might be broken or deformed and then it will be short circuited it causes the generating heat smoke rupture or flam...

Страница 12: ...ging and storage let it take out from equipment or charger and do not use it If an abnormal battery is used it will generate heat smoke rupture or flame 5 Charging Time Do not continue to charge battery over specified time If the battery is not finished charging over regulated time let it stop charging There is possibility that the battery might generate heat smoke rupture or flame 6 Leakage Do no...

Страница 13: ...ead the manual before using the battery and let it keeps after reading And also please reread if necessary 5 Charging Method Please read the manual of specified charger about charging method 6 First Time Use When the battery has rust bad smell or something abnormal at first time using do not use the equipment and go to bring the battery to the shop which it was bought 7 Used by Children In case yo...

Страница 14: ...e And also consult SANYO about the high rate current rapid charge and special application such as extreme condition and or environment 17 Notice for Battery Swelling There is a possibility that swelling occur in usage of prismatic type cells Regarding thickness of battery the specified value described on the drawing is the thickness after 500cyc under 4 3 as specified in paragraph 4 3 Therefore th...

Страница 15: ......

Отзывы: