background image

 

Title 

Specifications of Lithium Ion battery (Prismatic Type) 

page 

3/13 

4.  Electrical  Characteristics

 

Item 

Test Method 

Criterion 

4.1 Charge   

Full Charge 

The  charger  supply  1.88A  constant  current  until 
battery  voltage  reaches  4.20V,  then  be  changed  at 
constant voltage of

 

4.20V while tapering the charge 

current.  Charging  time  is  3.0hours  in

 

all.  Charging 

temperature is 25

 

 

4.2 Capacity 

Within 1hour after fully charged at 25

, discharge 

at

 

0.37A continuously down to 2.75V end voltage 

at 25

 

300min. or more 

Within  1hour  after  fully  charged,  discharge  at 

1.88A continuously down to 2.75V end voltage. 

 

54min. or more 

4.3 Cycle Life 

The  cell  shall  be  repeated  500  charge/discharge 
cycles  at  25

,  charged  at  CC-CV  (1.88A-4.20V) 

for  3.0hours,  discharged  at  1.88A  to  2.75V  end 
voltage.  After  500cycles,  discharging  time  is 
measured as specified in paragraph 4.2 

 

32min.  or  more 

4.4 Temperature 

Within 1hour after fully charged at 25

, the cell is 

stored  at  0

  for  3hours.  Discharge  time  is 

measured as specified in paragraph 4.2

② 

at 0

30min.  or  more 

Within 1hour after fully charged at 25

, the cell is 

stored  at  60

  for  3hours.  Discharge  time  is 

measured  as  specified  in  paragraph  4.2

  at 

60

 

50min.  or  more 

4.5 Full Charged 

State Storage 

After  fully  charged  at  25

,  stored  for  10days  at 

60

  and  rested  at  25

  for  3hour.  Discharge 

time is measured as specified in paragraph 4.2

 

35min.  or  more 

Then  next  discharge  time  is  measured  as 
specified in paragraph 4.2 

 
 
 
 
 
 

45min.  or  more 

File  No 

UF103450-849 

Energy Company, SANYO Electric Co., Ltd. 

Portable Rechargeable Battery Business Group 

Lithium-Ion  Battery  Business  Unit 

Содержание UF103450P-NETE-5

Страница 1: ......

Страница 2: ......

Страница 3: ...0 40 3 9 Internal Resistance less than 100mΩ AC Impedance 1kHz 3 10 Weight less than 39 8g 3 11 Operating Temperature Charge 0 40 Discharge 20 60 3 12 Surroundings Temperature Range for Shipped Battery less than 1month 20 50 less than 3months 20 40 Percentage of recoverable capacity 80 2 less than 1year 20 20 1 Maximum discharge current as a single cell state is as above stated However after assem...

Страница 4: ...ged at CC CV 1 88A 4 20V for 3 0hours discharged at 1 88A to 2 75V end voltage After 500cycles discharging time is measured as specified in paragraph 4 2 32min or more 4 4 Temperature Within 1hour after fully charged at 25 the cell is stored at 0 for 3hours Discharge time is measured as specified in paragraph 4 2 at 0 30min or more Within 1hour after fully charged at 25 the cell is stored at 60 fo...

Страница 5: ...ne delivered a week before at most The test shall be performed at 25 2 Standard temperature of second grade adopted in JIS Z 8703 Standard Test Conditions 65 20 Standard humidity of twentieth grade adopted in JIS Z 8703 Standard Test Conditions The grade of voltmeter and ammeter used in the test shall be higher than class 0 5 adopted in JIS C 1102 Electric Indicator 5 Design Construction A cell sh...

Страница 6: ...ould be 0 40 Discharge Discharge current must be below 2 00A cell Discharge temperature range should be 20 60 Discharge end voltage must be over 2 75V cell Over Discharge Do not over discharge a battery below 2 0V cell Battery position in PDA and charger To avoid degradation of battery performance by heat a battery should set the place apart from heat generating electronic parts inside PDA and cha...

Страница 7: ...the cell voltage or the voltage of cell block will be over 4 25V However in case that the charge system can control the cell voltage or the voltage of cell block within 4 25V the overcharge protection can be controlled near 4 25V Over discharge protection At the voltage range 2 20 2 40V cell over discharge protection should work Then discharge current shall be shut down and consumption current is ...

Страница 8: ...pping charge date and same capacity rank cells and use within 20mV voltage difference Lot number shipping charge date and capacity rank are on carton label when SANYO shipping for series When the cells are connected in series the discharge end voltage should be 3 0V cell 10 3 Precautions on Terminals of Cell Do not over stress or rotate at positive terminal plate and negative cap By over stress it...

Страница 9: ...If the cell voltage drops to 0V as a result of storage and the cell is charged at this condition the FET on the protection circuit may generate heat The charger must have the pre charge system Pre charge current of charger should be approximately 0 18A When the battery voltage becomes 3 0V cell standard charge should be started When the battery voltage is less than 3 0V cell even after the set per...

Страница 10: ...in individual cells and then it causes the generating heat smoke rupture or flame In addition do not use the battery under the heated place more than 80 for same reason 3 Charger and Charge Condition Do use the specified charger and observe charging requirement If the battery is charged with unspecified condition under high temperature over the regulated value excessive high voltage or current ove...

Страница 11: ...cuit in the battery is broken the battery will be charged at abnormal voltage or current and abnormal chemical reaction might occur It might cause leakage heat smoke rupture and or fire 10 Penetration Do not drive a nail into the battery strike it by hammer or tread it As the battery might be broken or deformed and then it will be short circuited it causes the generating heat smoke rupture or flam...

Страница 12: ...ging and storage let it take out from equipment or charger and do not use it If an abnormal battery is used it will generate heat smoke rupture or flame 5 Charging Time Do not continue to charge battery over specified time If the battery is not finished charging over regulated time let it stop charging There is possibility that the battery might generate heat smoke rupture or flame 6 Leakage Do no...

Страница 13: ...ead the manual before using the battery and let it keeps after reading And also please reread if necessary 5 Charging Method Please read the manual of specified charger about charging method 6 First Time Use When the battery has rust bad smell or something abnormal at first time using do not use the equipment and go to bring the battery to the shop which it was bought 7 Used by Children In case yo...

Страница 14: ...e And also consult SANYO about the high rate current rapid charge and special application such as extreme condition and or environment 17 Notice for Battery Swelling There is a possibility that swelling occur in usage of prismatic type cells Regarding thickness of battery the specified value described on the drawing is the thickness after 500cyc under 4 3 as specified in paragraph 4 3 Therefore th...

Страница 15: ......

Отзывы: