ALARM RECORDING
By connecting the ALARM IN terminal to a door switch,
an interphone, etc., a recording can be done only when
necessary.
Alarm Recording Setting
Alarm recording is performed when there is an input
(trigger) at the ALARM IN terminal, “AL” is displayed on
the digital display.
X
Make all necessary connections.
X
The alarm triggers are received while in recording and
stop modes.
X
Follow the Before starting steps, under “NORMAL
RECORDING”.
1
Set the ALARM SPEED switch to the desired
recording speed.
2H . . . . . 2-hour mode recording
12H . . . . 12-hour mode recording
NC . . . . . Recording at the speed already set
2
Set the ALARM DURATION switch to the desired
recording duration.
20S. . . . . 20-second recording
PROG. . . Recording for the duration set for the
“ALARM DURATION” item in the (SET
UP 3) menu.
CC . . . . . Recording as long as the alarm signal is
being input (minimum 5 seconds)
3
Press the MENU button until the (SET UP 3) menu is
displayed.
@@@@@@@<SET@UP@3>
*ALARM@MODE@@@@@@@Y1
*ALARM@DURATION@@@20S
*TAPE@IN@MODE@@@@@STOP
*TAPE@END@MODE@@@@REW
*TAPE@END@OUT@@@@@-3M
*CLOG@DETECT.@@@@@Y
4
Press the
l
(or
j
) button to set the desired alarm mode.
Y1. . . . . . Alarm recording is done when there is an
alarm trigger.
Y2. . . . . . Alarm recording is done only when there
is an alarm trigger during programmed
timer recording.
Y3. . . . . . Alarm recording is done only if there is
an alarm trigger and the VCR is not in
programmed timer recording mode.
Y4. . . . . . Alarm recording is done only when there
is an alarm trigger during programmed
timer recording duration. Timer recording
is not possible.
N . . . . . . Alarm recording is not performed even if
there is an alarm trigger.
If the ALARM DURATION switch is set to the “PROG.”
position, please continue with steps
5
and
6
.
5
Press the
*
button, until the “ALARM DURATION”
setting is flashing.
6
Press the
l
(or
j
) button, to select the desired alarm
recording duration (20S, 40S, 1M, 2M, 3M, 4M, 5M,
or CC).
20S-5M . . Recording only for the displayed duration
CC . . . . . Recording as long as the alarm signal is
being input (minimum 5 seconds)
7
Press the SEARCH/AUDIO ON button to save the
settings.
NOTES:
X
During alarm recording all buttons are disabled.
X
If “OFF” is displayed on the digital display, alarm
recording is not possible in order to prevent the
recorded tape to be recorded over.
To cancel the “OFF” display, press the STOP, EJECT,
FF, REW or PLAY button.
X
If an alarm trigger is received while alarm recording is
in progress, recording duration for the second alarm
will be calculated from that point. The alarm counter will
register the alarm, but it will not be found during an
alarm scan and alarm search.
X
If there is a power failure during alarm recording, and
the power is restored within the recording set duration,
alarm recording will continue.
X
If the alarm recording duration is short, the alarms may
not be found during an alarm scan or an alarm search.
If the alarms are going to be reviewed using alarm
scan or alarm search, then in 2-hour mode, 20-second
or more recording duration should be used.