-4-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
60
60
0-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
46
46
0-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
6
6
0-100
1 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
60
60
0-100
1 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
15
0-100
17 Temp C Warning Offset
(Temp)
15
0-100
18 Temp B-A Warning Offset
(Temp)
100
0-100
19 Temp C-A Warning Offset
(Temp)
100
0-100
0 Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
15
0-100
1 Temp B Warning Offset
(Time)
0
0-100
Temp C Warning Offset
(Time)
0
0-100
Temp B-A Warning Offset
(Time)
40
0-100
4 Temp C-A Warning Offset
(Time)
40
0-100
Group
254
Fan Control range Setting (temp./Voltage)
Normal
Ceiling
0 High Fan Control Min Temp
Temp Senser Control Start/End Temp.
at High
8
8
0-100
1 High Fan Control Max Temp
4
4
0-100
High Fan1 Min
Fan voltage value at High (unit: 0.1V)
95
95
0-55
High Fan1 Max
15
15
0-55
4 High Fan Min
85
85
0-55
5 High Fan Max
10
10
0-55
6 High Fan Min
75
75
0-55
7 High Fan Max
77
77
0-55
8 High Fan4 Min(LAMP1)
-
-
0-55
9 High Fan4 Max(LAMP1)
-
-
0-55
10 High Fan5 Min(LAMP1)
-
-
0-55
11 High Fan4 Max(LAMP1)
-
-
0-55
1 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Normal
8
8
0-100
1 Normal Fan Control Max
Temp
4
4
0-100
14 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
80
80
0-55
15 Normal Fan1 Max
15
15
0-55
16 Normal Fan Min
75
75
0-55
17 Normal Fan Max
10
10
0-55
18 Normal Fan Min
70
70
0-55
19 Normal Fan Max
70
70
0-55
0 Normal Fan4 Min
-
-
0-55
1 Normal Fan4 Max
-
-
0-55
Normal Fan5 Min
-
-
0-55
Normal Fan5 Max
-
-
0-55
4 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Eco
6
6
0-100
5 Eco Fan Control Max Temp
4
4
0-100
6 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
65
65
0-55
7 Eco Fan1 Max
115
115
0-55
8 Eco Fan Min
70
70
0-55
9 Eco Fan Max
110
110
0-55
0 Eco Fan Min
5
5
0-55
1 Eco Fan Max
5
5
0-55
Eco Fan4 Min(LAMP1)
-
-
0-55
Eco Fan4 Max(LAMP1)
-
-
0-55
4 Eco Fan5 Min(LAMP1)
-
-
0-55
Содержание Think GAIA PLC-WXU700
Страница 67: ... 67 IC Block Diagrams FA7701 DDC Control IC7841 FA7703 Fan Power Control IC7811 Component2 ...
Страница 68: ... 68 IC Block Diagrams MP2106 DC DC Converter IC5721 IC8018 IC8019 FA5502 P F Control IC601 ...
Страница 70: ... 70 IC Block Diagrams L3E07111 LCD Driver Gamma Correction IC401 LM4889 Audio Output IC5031 ...
Страница 72: ... 72 IC Block Diagrams STR Z2156 Power OSC IC651 TE7783 Parallel I O Expander IC1802 ...
Страница 73: ... 73 IC Block Diagrams MP2307 DC DC Conventer IC5860 IC5842 ...
Страница 111: ...KY7 WXU70000 111 Mechanical Parts List 527 528 L14 L10 L03 L15 L07 L16 L13 L09 L06 L08 In the Optical Unit L11 L14 ...
Страница 113: ...KY7 WXU70000 113 Mechanical Parts List ...
Страница 114: ... KY7AC July 200 DC 300 Printed in Japan SANYO Electric Co Ltd ...
Страница 132: ...A16 PCB_KY7AC NO DATA ...