-3-
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1. Turn off the projector and disconnect the AC cord. Allow the projector to
cool for at lease 45 minutes.
2. Remove a screw with a screwdriver and remove the lamp cover.
3. Remove 2 screws and pull out the lamp assembly by grasping the han-
dle.
4. Replace the lamp assembly securely and tighten 2 screws.
5. Place the lamp cover and tighten a screw.
6. Connect the AC cord to the projector and turn on.
Note:
- Do not reset the Lamp Replacement Monitor Timer, except after the
lamp is replaced.
- The projector can not be turned-on with the lamp cover removed,
because when the lamp cover is removed, the interlock switch is also
released to switch off the mains power for safety.
7. Reset the lamp replacement monitor timer, see below explanation.
■
Lamp Replacement
How to reset the Lamp Replacement
Monitor Timer
1. Turn the projector on, and press the MENU button
and the ON-SCREEN MENU will appear. Press the
POINT LEFT/RIGHT buttons to select SETTING and
press the SELECT button. Another dialog box SET-
TING MENU will appear.
2. Press the POINT DOWN button and a red arrow icon
will appear. Move the arrow to “Lamp age”, and then
press the SELECT button. The message “Lamp
replace monitor Reset?” is displayed.
3. Select [Yes] to reset the Timer.
Please refer to the owners manual for further informa-
tion.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
How to check the Accumulated
Illumination Time
The LAMP REPLACEMENT indicator will illuminate
when the accumulated illumination time of the lamp
reaches 1000 hours. This is to indicate that lamp
replacement is required.
You can check the accumulated illumination time of
the lamp by following procedure.
1. Press and hold the pointer
▲
on the projector for
more than 20 seconds.
2. The accumulated illumination time is displayed on
the right bottom corner of the screen. For example,
when “Lamp Age 123 hours” is displayed, the
accumulated illumination time of the lamp is 123
hours. This will disappear in 5 seconds.
Lamp cover
Lamp Assembly
Handle
Lamp Age
0123 Hours
Accumulated Illumination Time
ORDER REPLACEMENT LAMP
Type No.
Service Parts No.
POA-LMP31
610 289 8422
Содержание SW15 - PLC SVGA LCD Projector
Страница 34: ...MK6 SW1500 Mechanical Parts List 34 45 45 45 48 47 62 ...
Страница 35: ...MK6 SW1500 35 Mechanical Parts List 63 22 48 69 45 45 45 45 21 48 ...
Страница 38: ...MK6 SW1500 38 ...
Страница 39: ...MK6 SW1500 39 ...
Страница 40: ... MK6AA Apr 2001 2000 SI Printed in Japan SANYO Electric Co Ltd ...