OUTPUT TERMINALS
SW OUT Terminal
When recording, a pulse signal is output at the SW OUT
terminal.
This terminal is usually connected to the switch input
(SW IN) of devices like a camera switcher unit, or a
quad compressor.
SW OUT Terminal Output Setting
1
Press the MENU button until the (SET UP 4) menu
is displayed.
ø
The FIELD (or FRAME) setting is flashing.
@@@@@@@<SET@UP@4>
öSW@OUT
@@FIELD@@@@@@@@@01
@@TIMING@@@@@@@@FIELD
@@8H@@@@@@@@@@@@Y
öTHREAD@CHECK@@@Y
öVIDEO@LOSS@@@@@N
öREC@SPEED@@@@@@N
öVERTICAL@SYNC@@Y
NOTE:
œ
If “TIMING” is set to FRAME (see step
4
),
“FRAME” will be indicated instead of “FIELD”.
2
Turn the SHUTTLE ring, to set the desired pulse
signal interval.
Available settings are:
FIELD . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field
FRAME . . . . . 01, 02, 03, 04, 05, 10, 30 or 60
frame
3
Turn the JOG dial clockwise until the “TIMING”
setting is flashing.
4
Turn the SHUTTLE ring, to set “FIELD” or “FRAME”.
FIELD . . . . . . 1 pulse is output after each set
number of fields.
FRAME . . . . . 1 pulse is output after each set
number of frames.
5
Turn the JOG dial clockwise until the “8H” setting is
flashing.
NOTE:
œ
If the TAPE SELECT switch to the “E-180”, “6H”
will be indicated instead of “8H”.
6
Turn the SHUTTLE ring, to set the desired “8H”
mode.
Y. . . . . . . . . . When recording in 8-hour mode,
a pulse signal is output.
N. . . . . . . . . . When recording in 8-hour mode,
a pulse signal is not output.
7
Press the SEARCH button to save the settings.
SERIES OUT/NON REC OUT terminal
setting
The output at the SERIES OUT/NON REC OUT
terminal can be set.
1
Press the MENU button until the (SET UP 1) menu
is displayed.
@@@@@@@<SET@UP@1>
öSUMMER@TIME@SET@@USE
@@@@@@@@WEEK@MONTH@TIME
@ON@@@LST-SUN@@03@02:00
@OFF@@LST-SUN@@10@02:00
öOUTPUT@@@@@@@@SERIES
öCLOCK@SET
@15-10-99@FRI@@15:20:00
öREMOTE@@@@@@@@EJECT
öLANGUAGE-LANGUE-SPRACHE
@@@ENGLISH
2
Turn the JOG dial, until the “OUTPUT” setting is
flashing.
3
Turn the SHUTTLE ring, to select the desired
output mode.
SERIES . . . . If during series recording, the
counter reading reaches
7
H
57
M
00
S
or the tape reaches
the end, a LOW signal (0 V) is
output. The LOW (0 V) signal is
output for about 70 seconds after
the end of the tape is reached.
NON REC. . . If during recording the VCR
enters a mode other than
recording (i.e. recording pause,
stop mode, etc.), a LOW signal (0
V) is output. If recording is
resumed, then a HIGH signal (5
V) is output.
If in the (SET UP 2) menu, in the
BUZZER section, WARNING is
set to “Y”, a buzzer will be heard
while the VCR is in non recording
mode. The buzzer will stop if the
STOP button is pressed (the
output signal will remain LOW (0
V)).
4
Press the SEARCH button to save the setting.
5V (H)
0V (L)
(Output impedance: 5.7 k
Ω
)
FIELD: 20 msec.
FRAME: 5 msec.
RR4QR/EX (SRT-7168P GB) Thu. Jan., 13/2000
English
35