SM830043
– 70 –
4
4. Service procedures
Fig. 47
Multimeter
Fan motor
Capacitor
0643_X_S
(3)
Checking the Electrical Parts
1
Power transformer (TR1) ................. Indoor unit
*Measure the coil resistance.
•
Primary 220-240 V ; Measure the resistance between two WHT lead wire
terminals of socket connected to power transformer.
•
Secondary 10.6V ; Measure the resistance between two BRN lead wires.
Refer to “1–3–(A) Other component specifications”.
2
Indoor fan motor (FMI) ............... Indoor unit
*Measure the coil resistance.
•
Measure the resistance between each terminal of the socket connected to
the indoor fan motor.
Refer to “1–2–(A) Major component specifications”.
3
Outdoor fan motor (FMO) ........... Outdoor unit
*Measure the coil resistance.
•
Measure the resistance in the same manner as explained above
2
.
Refer to “1–2–(B) Major component specifications”.
4
Fan motor capacitor ............ Both in indoor and outdoor unit
•
Remove the lead wires from the capacitor terminals,
and then place a probe on the capacitor terminals as
shown in Fig. 47. Observe the deflection of the pointer,
setting the resistance measuring range of the multimeter
to the maximum value.
•
The capacitor is “acceptable” if the pointer bounces to a
great extent and then gradually returns to its original
position.
NOTE
The range of deflection and the deflection time differ according to
the capacity of the capacitor.
Содержание SPW-T483GS56 ? SPW-C483G8 (/M)
Страница 6: ... 6 SM830043 ...
Страница 28: ... 28 SM830043 1 Specifications 1 ...
Страница 32: ... 32 SM830043 2 2 Processes and functions ...
Страница 54: ...SM830043 54 3 3 Electrical data ...