8-2. Dry Operation (Dehumidification)
Dry operation uses the ability of the cooling cycle to remove moisture from the air, but by running at low level to
dehumidify without greatly reducing the room temperature. The air conditioner repeats the cycle of turning ON
and OFF automatically as shown in the chart below according to the room temperature.
NOTE
< Cooling operation >
T+2
°
C
T-1
°
C
T+1
°
C
< Monitor zone >
Room temp. 15
°
C
T-1
°
C
T
°
C
Room temp. 15
°
C
< Dry A zone >
Compressor :
FMI (indoor fan) :
Continuous operation
Indoor fan operates with rhythm airflow.
< Dry B zone >
Compressor :
FMI (indoor fan) :
Intermittent operation
(ON for 3 minutes and OFF for 9 minutes)
Indoor fan operates with rhythm airflow.
When room temp.
goes down
When room temp.
goes up
T : Set temp.
The air conditioner operates in cooling mode.
Both the indoor and outdoor units stop.
Intermittent ventilation occurs by switching the indoor fan speed between L and LL.
DRY operation does not occur when the room temperature is 15
°
C or less, which is the monitor zone.
When the compressor stops, the indoor fan stops as well.