9
6. ELECTRICAL DATA
6-1 Electrical Characteristics
Model
SA– 93AH
COOLING
Fan Motor
Compressor
Complete Unit
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.45
3.95
4.4
Power Input
kW
0.110
0.940
1.05
Full Load Conditions Running Amps.
A
0.45
5.45
5.9
Power Input
kW
0.110
1.280
1.39
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Fan Motor
Compressor
Complete Unit
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.45
3.35
3.8
Power Input
kW
0.110
0.790
0.90
Full Load Conditions Running Amps.
A
0.45
5.25
5.7
Power Input
kW
0.110
1.220
1.33
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.