How to test run the air conditioner
1. Switch on the power source.
2. Press the ON/OFF button on the remote control unit
once.
3. Set the operation selector switch of the indoor unit
to the TEST position. This starts the fan, producing
uncooled forced air. (Fig. 7)
4. After 3 minutes, the system shifts into cooling oper-
ation, and cool air will start to be felt. Cooling oper-
ation with the switch at the TEST position is unaf-
fected by the room temperature.
5. After stopping the test run, turn the operation selec-
tor switch of the indoor unit to the OFF position
once, then move to ON position. (Fig. 7)
6. Press the ON/OFF button on the remote control unit
to stop the air conditioner.
If the unit does not operate and the OPERATION lamp
on the unit is blinking after going through the proce-
dure, check the wiring between the units.