-64-
to enter the service mode
To enter the “Service Mode”, press and hold the
MeNu
and
SeLect
button
for more than 3 seconds. The service
menu appears on the screen as follows.
to adjust service data
Select the adjustment group no. by pressing the
MeNu
button
(increase) or
SeLect
button
(decrease), and
select the adjustment item no. by pressing the pointer
U
or
V
button
, and change the data value by pressing the
W
or
X
button
. Refer to the “Service Adjustment Data Table” for further description of adjustment group no., item
no. and data value.
to exit the service mode
To exit the service mode, press the
oN/StANd-BY button
.
Service Adjustment Menu Operation
Memory ICs on the main board stores the data for the
service adjustments, and should not be replaced ex-
cept for the case of defective device.
If replaced, the re-adjustments are required following to
the “Electrical Adjustments”.
The data of lamp replacement counter is stored in the
Memory IC.
Please note that the lamp replace counter will be reset
when the memory IC is replaced.
(Lamp replace counter cannot be set to the previous
value.)
●
caution to memory Ics replacement
When memory ICs are replaced with new one, the CPU
writes down the default data of the service adjustments
to the replaced ICs as the mentioned on the service ad-
justment table. As these data are not the same data as
factory shipped data, it should be required to perform
the re-adjustments following to the “Electrical Adjust-
ments”.
Please note that in this case the lamp replace counter
will be reset.
●
caution of Main Board replacement (in the case
memory Ics are not defective)
When the main board is replaced, memory ICs should
be replaced with the one on previous main board. After
replacement, it should be required to perform the re-ad-
justments following to the “Electrical Adjustments”.
In this case, the value of lamp replace counter can be
kept as before.
Memory IC (IC302, IC802) Replacement
Service Mode
Input
Video
Group
No.
Data
0
0
32
Ver. R 1.00
Data value
Item No.
Group No.
Electrical Adjustments
Содержание PLV-WF20
Страница 163: ... 163 Parts Location Diagrams KY3 WF2000 Integrator In Assembly S06 L04 S06 Integrator Out PBS Assembly S06 L01 S06 L04 ...
Страница 164: ... 164 Parts Location Diagrams KY3 WF2000 MIrror R Assembly S06 L13 Relay In Assembly L11 ...
Страница 165: ... 165 Parts Location Diagrams KY3 WF2000 L20 L05 L10 L07 L14 L19 L10 L08 L09 In the Optical Unit L14 ...
Страница 166: ... 166 Parts Location Diagrams KY3 WF2000 L15 L12 L16 In the Optical Lamp Unit ...
Страница 211: ...Key No Part No Description Key No Part No Description KY3 WF2000 211 Electrical Parts List ...
Страница 212: ... KY3A Feb 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...
Страница 228: ...A14 SCH_KY3A 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 A B C D E F G H I J K L A B C D E F G H I J K L NO DATA ...