Group/
Item
ITEM NAME
FUNCTION
INITIAL
RANGE
NOTE
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Room)
42
43
33
33
30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at Normal
(Panel)
62
61
56
64
30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at Normal
(Lamp)
69
68
66
63
30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at Eco (Room)
44
43
37
36
30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at Eco (Panel)
58
58
56
55
30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at Eco (Lamp)
65
62
62
61
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset (Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset (Temp)
5
0-100
17 Temp C Warning Offset (Temp)
5
0-100
18 Temp B-A Warning Offset (Temp)
0
0-100
19 Temp C-A Warning Offset (Temp)
0
0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
3
0-5
21 Temp B Warning Offset (Time)
3
0-5
22 Temp C Warning Offset (Time)
3
0-5
23 Temp B-A Warning Offset (Time)
3
0-5
24 Temp C-A Warning Offset (Time)
3
0-5
PLC-XU78
Group 254 Fan Control Range Setting (Temp./Voltage)
Normal
Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 Not used
9999
1 Not used
9999
2 Not used
9999
3 Not used
9999
4 Not used
9999
5 Not used
9999
6 Not used
9999
7 Not used
9999
8 Not used
9999
9 Not used
9999
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p at
Normal
28
28
20
20
20-100
11 Normal Fan Control Max Temp
36
37
20
20
20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit: 0.1V)
65
70
120
125
0-255
13 Normal Fan1 Max
120
125
120
125
0-255
14 Normal Fan2 Min
80
95
125
125
0-255
15 Normal Fan2 Max
125
125
125
125
0-255
16 Not used
9999
9999
17 Not used
9999
9999
18 Not used
9999
9999
19 Not used
9999
9999
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p at Eco
28
28
20
20
20-100
21 Eco Fan Control Max Temp
37
37
20
20
20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
50
55
100
105
0-255
23 Eco Fan1 Max
100
105
100
105
0-255
24 Eco Fan2 Min
60
65
75
80
0-255
25 Eco Fan2 Max
75
80
75
80
0-255
26 Not used
9999
9999
27 Not used
9999
9999
28 Not used
9999
9999
29 Not used
9999
9999
PLC-XU75
Group 254 Fan Control Range Setting (Temp./Voltage)
Normal
Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 Not used
9999
1 Not used
9999
2 Not used
9999
3 Not used
9999
4 Not used
9999
5 Not used
9999
6 Not used
9999
Содержание PLC-XU75
Страница 60: ... 60 IC Block Diagrams FA5502 P F Control IC621 HIN202EIB RS 232C Driver IC3801 ...
Страница 61: ... 61 IC Block Diagrams L3E07110 LCD Driver Gamma Correction IC401 L3E06150 D A S H LCD Driver IC501 IC531 IC561 ...
Страница 62: ... 62 IC Block Diagrams L3E01060 Level Shift IC2501 IC2531 IC2561 PW190 Scaler IC301 ...
Страница 63: ... 63 LM4889 Audio Output IC5031 STR Z2156 Power OSC IC641 IC Block Diagrams ...
Страница 88: ...KH3 XU7800 KZ3 XU7500 88 Mechanical Parts List L11 L07 L12 L16 L04 L17 L10 L09 L03 L05 L07 In the Optical Unit ...
Страница 90: ... KH3AC Aug 2007 DC 350 Printed in Japan SANYO Electric Co Ltd ...
Страница 104: ...A12 PCB_KH3AC NO DATA ...