-9-
1. Receive the 16-step grey scale composite video sig-
nal with
Video
mode.
. Enter the service mode.
3. Connect an oscilloscope to test point “
tP_G1
” (+)
and chassis ground (-).
4. Select group no. “
100
”, item no. “
6
” and change data
value to adjust amplitude “
a
” to be
2.2 ±0.1V
.
(a)
white level
white level
.
50% White adjustment [Video]
1. Receive the 16-step grey scale composite video sig-
nal with
Video
mode.
. Enter the service mode, select group no. “
100
” item
no. “
7
” (Red) or “
8
” (Blue), and change Data values
respectively to make a proper white balance.
Confirm that the same white balance is obtained in video
and computer input.
⁄0
White Balance adjustment [Video]
Note On White Uniformity Adjustment
If you find the color shading on the screen, please ad-
just the white uniformity by using the proper computer
and “Color Shading Correction” software supplied sep-
arately.
The software can be ordered as follows;
coLor SHAdING correctIoN Ver. 4.00
Service Parts No.
645 075 9611
1. Enter the service mode,
. Receive the 16-step gray scale computer signal with
computer1 [rGB]
mode.
3. Select group no. “
100
” item no. “
7
” (Red) or “
8
” (Blue),
and change Data values respectively to make a prop-
er white balance.
Confirm that the same white balance is obtained in video
and computer input.
,
White Balance adjustment [PC]
1. Enter the service mode.
. Receive the 16-step grey scale computer signal with
computer1 [rGB]
mode.
3. Connect an oscilloscope to test point “
tP_G1
” (+)
and chassis ground (-).
4. Select group no. “
100
”, item no. “
6
” and change data
value to adjust amplitude “
a
” to be
1.6 ±0.1V
.
(a)
white level
white level
m
50% White adjustment [PC]
1. Enter the service mode.
. Receive the 50%-Whole Gray computer signal with
computer1 [rGB]
mode.
3. Select group no. “
100
”, item no. “
92
” and change
data value to “
2
” to reduce the panel frequency.
4. Project only green light component to the screen.
5. Select group no. “
101
”, item no. “
1
” and change
data value to obtain the minimum flicker on the
screen.
6. Project only red light component to the screen.
7. Select item no. “
0
” and change data value to obtain
the minimum flicker on the screen.
8. Project only blue light component to the screen.
9. Select item no. “
2
and change data value to obtain
the minimum flicker on the screen.
10. Select group no. “
100
”, item no. “
92
” and change
data value to “
0
” to reset the panel frequency.
n
Common Center adjustment
Содержание PLC-XU75
Страница 60: ... 60 IC Block Diagrams FA5502 P F Control IC621 HIN202EIB RS 232C Driver IC3801 ...
Страница 61: ... 61 IC Block Diagrams L3E07110 LCD Driver Gamma Correction IC401 L3E06150 D A S H LCD Driver IC501 IC531 IC561 ...
Страница 62: ... 62 IC Block Diagrams L3E01060 Level Shift IC2501 IC2531 IC2561 PW190 Scaler IC301 ...
Страница 63: ... 63 LM4889 Audio Output IC5031 STR Z2156 Power OSC IC641 IC Block Diagrams ...
Страница 88: ...KH3 XU7800 KZ3 XU7500 88 Mechanical Parts List L11 L07 L12 L16 L04 L17 L10 L09 L03 L05 L07 In the Optical Unit ...
Страница 90: ... KH3AC Aug 2007 DC 350 Printed in Japan SANYO Electric Co Ltd ...
Страница 104: ...A12 PCB_KH3AC NO DATA ...