-30-
Electrical Adjustments
1. Enter the service mode.
. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select group no. “
250
”, item
no. “
0
” and change data value to adjust voltage to be
5.0 ±0.1V
.
3. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select item no. “
1
” and change
data value to adjust voltage to be
13.5 ±0.1V
.
4. Connect a digital voltmeter to test point “
tPFANB
” (+)
and chassis ground (-). Select item no. “
2
” and change
data value to adjust voltage to be
4.5 ±0.1V
.
5. Connect a digital voltmeter to test point “
tPFANB
” (+)
and chassis ground (-). Select item no. “
3
” and change
data value to adjust voltage to be
13.5 ±0.1V
.
6. Connect a digital voltmeter to test point “
tPFANc
” (+)
and chassis ground (-). Select item no. “
4
” and change
data value to adjust voltage to be
5.0 ±0.1V
.
7. Connect a digital voltmeter to test point “
tPFANc
” (+)
and chassis ground (-). Select item no. “
5
” and change
data value to adjust voltage to be
13.5 ±0.1V
.
2. Fan control adjustment
1. Enter the service mode.
. Receive the 16-step grey scale computer signal
with
computer 1 [rGB]
mode.
3. Select group no. “
101
”, item no. “
12
” to ad-
just the voltage of
tP_VMIdG
to be
7.00
±0.01V
.
4. Select group no. “
101
”, item no. “
14
” to adjust
the voltage of
tP35G
to make the amplitude
“
d[Vpp]
” to be
10.00 ±0.05V
.
3 .reference Voltage Adjustment
㪛㩷㪲㪭㫇㫇㪴
* Before setting, you need to check which type of LCD
panel is placed on the projector according to the item
"LCD Panel/Prism Ass'y removal" in the chapter "Optical
Parts Disassembly".
1. Enter the service mode.
. Panel Type Check
Select group no. “
290
”, item no. “
0
”. Check the data
value as follows;
Data value: 0 For L-Type of LCD Panel
Data value: 0 For R-Type of LCD panel
3. Panel Type Setting
Select group no. “
290
”, item no. “
1
” and change data
value from 10 to 0 or 0 depending on your LCD
Panel type. When the data value reaches 0 or 0,
it returns to 10 quickly. The gamma-characteristics
changes according to your selection.
1. Panel type check and Setting
Note:
Be careful to take this adjustment. The value of
gamma adjustment data will be reset and cannot be
restored if you change the mode of LCD panel type.
After replacing the Power Board readjust the Output
voltage adjustment as follows.
1. Connect a digital voltmeter to RED WIRE (+) and
BLACK WIRE (-).
. Adjust the voltage by using VR61 as following.
AC Input
Reading
30V
374V ±1V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
* This adjustment is not required even if the power
board is replaced because this adjustment is carried
out before parts shipment.
output Voltage adjustment
Содержание PLC-XU305A
Страница 66: ... 66 IC Block Diagrams FA5550NG P F Control IC621 FA7701 DC DC Converter IC5601 ...
Страница 67: ... 67 IC Block Diagrams HIN202EIB RS 232C Driver IC3801 L3E06170 D A S H LCD Driver IC501 IC531 IC561 ...
Страница 70: ... 70 IC Block Diagrams MR4010 Power OSC IC631 TE7783 Parallel I O Expander IC1802 ...
Страница 71: ... 71 IC Block Diagrams FA7703 DC DC Converter IC5651 ...
Страница 108: ... KG5AE KB5AE December 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...