-9-
Maintenance
Cleaning the Air Filter
Turn off the projector, and unplug the AC power cord
from the AC outlet.
First, clean up the dust on the projector and around the
air vents.
1
2
Filter prevents dust from accumulating on the optical elements inside the projector. Should the filter becomes
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup and
adversely affect the life of the projector. If a “Filter warning” icon (yellow or red) appears on the screen and the
WARNING FILTER indicator lights or blinks, clean the filter immediately. Clean the filter by following the steps
below.
Pull out the filter cover from the projector and then re-
move the filter.
3
Reinstall the filter into the projector properly.
5
cAutIoN
Do not operate the projector with the filter removed.
Dust may accumulate on the optical elements de-
grading picture quality.
Do not put anything into the air vents. Doing so may
result in malfunction of the projector.
Gently clean the filter by using a brush or blower.
WArNING: do not wash the filter with water and any
other liquid matter. otherwise the filter may be dam-
aged.
4
Reset the filter counter in the Setting Menu. See “Reset-
ting the Filter Counter” below.
6
Press and hold the
filter cover and pull
out the filter.
Filter cover
Filter
Filter
Filter cover
Be sure to reset the Filter counter after cleaning or replacing the filter.
Press the MENU button to display the On-Screen Menu.
Use the Point
7 8
buttons to move the red framed
pointer to the Setting Menu icon.
Use the Point
ed
buttons to move the red framed point-
er to Filter counter and then press the SELECT button.
A dialog box appears showing the total accumulated
time of the filter use, a timer setting option, and the re-
set option. Select Reset and the “Filter counter Reset?”
appears. Select [Yes] to continue.
1
2
Resetting the Filter Counter
Filter counter
NOTE: If the filter is heavily clogged and unable
to clean, replace it with a new one.
Consult your dealer for details.
Select Reset and the “ Filter
counter Reset?” appears.
Select [Yes],
then another
confirmation
box appears.
Select [Yes] again to reset
the Filter counter.
Another confirmation dialog box appears, select [Yes] to
reset the Filter counter.
3
replacement Filter Part No.: 910 330 7184
Содержание PLC-XT35
Страница 102: ... 102 IC Block Diagrams BA7078 Sync Seperator IC5321 FA7701V Switching Controller IC5641 ...
Страница 103: ... 103 IC Block Diagrams HIN202EIB RS 232C Driver IC3801 L3E01060 Level Shift IC2501 IC2531 IC2561 ...
Страница 104: ... 104 IC Block Diagrams L3E06150 Sample Hold IC501 IC531 IC561 L3E07111 Digital Gamma Shift LCD Driver IC401 ...
Страница 105: ... 105 IC Block Diagrams LM4889 Audio Output IC5121 NJW1141 Audio Control IC5001 ...
Страница 106: ... 106 IC Block Diagrams TE7783 Parallel I O Expander IC1801 PW190 Scan Converter System Control IC301 ...
Страница 107: ... 107 IC Block Diagrams CXA2229 Video SW Sync IC101 CXD3815 Video Decoder IC3101 ...
Страница 108: ... 108 IC Block Diagrams THS7347IPHPR PC1 PC2 SW IC5201 ...
Страница 134: ... 134 Mechanical Parts List KP3 XT3500 KP3 XT35L00 Condenser lens out assembly M07 L15 Relay lens out assembly L19 M08 ...
Страница 139: ... 139 Mechanical Parts List KP3 XT3500 KP3 XT35L00 ...
Страница 140: ... KP3A Nov 2007 DC 350 Printed in Japan SANYO Electric Co Ltd ...
Страница 152: ...A10 SCH_KP3A 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 A B C D E F G H I J K L A B C D E F G H I J K L NO DATA ...