Electrical Adjustment
Group/
Item
Item Name
Function
Initial
Range
Note
1 Filter Warning Offset Point 0
Fan Cloggle Detect Offset value. (Freq.)
* The value is set automatially after Caribra-
tion
1731
1812
0000~9999
2 Filter Warning Offset Point 1
2686
2818
0000~9999
3 Filter Warning Offset Point 2
3456
3598
0000~9999
4 Filter Warning Offset Point 3
4139
4288
0000~9999
5 Filter Warning Offset Point 4
4728
4948
0000~9999
6 Filter Warning Offset Point 5
5221
5522
0000~9999
7 Filter Warning Offset Point 6
5607
5988
0000~9999
8 Filter Warning Offset Point 7
5899
6332
0000~9999
9 * Not used
10 * Not used
11 * Not used
12 * Not used
13 Filter Warning Time
Cloggle Det. Time(min)
3
0 - 10
14 Fan-Add Filter Level 1
Additional Fan Freq. at Clogging Level1 (rpm)
1000
0000-9990
15 Fan-Add Filter Level 2
Additional Fan Freq. at Clogging Level2 (rpm)
2000
0000-9990
16 Filter Warning Calibration Range
Tolelance at Auto Adjustment
(1:±5rpm 2:±10rpm 10:±50rpm)
1
0~10
17 Filter Warning Calibration Time
Time to OK at Auto calibration (sec)
2
1~10
18 Filter Warning Calibration Error Log
Log of Auto calibration (Read only)
0: No Error
100-111: Fan Min Adj Error
200~211: Out of Torelance
255: Auto calibration not Executed
255
0~255
19 Filter Warning High Land Calibration
Error Log
High Land Calibration Error Log (Read only)
0: No Error
50: Cancelling Adj.
100-111: Fan Min Adj Error
200~211: Out of Torelance
255: Auto calibration not Executed
255
0~255
20 Filter Warning Calibration Temp
External Temp. at calibration execution(x10)
*Read only
260
260
-
21 Filter Warning Inclination Rpm
(to 26ºC)
Increase value of Threshold Rotation when
Temp increase 10ºC
(Lower then 26ºC Ext. temp)
80
0000-9999
22 Filter Warning Inclination Rpm
(over 26ºC)
Increase value of Threshold Rotation when
Temp increase 10ºC
(Higher then 26ºC Ext. temp)
90
0000-9999
23 Filter Warning Add Offset Rpm
Rotation correction due to Temp.
*Read only
-
-
Group 252 Fan Option
0 Fan Max Switch
0:Normal
1:Max Fixed (13.5V)
* HighLand Set is disable when setting Fan
Max
0
0-5
1 Safety Switch
Safety Exam FAN Control Switch
(0:Normal, 1:High Min, 2:High Max, 3:Normal
Min, 4:Normal Max, 5:Eco Min,6:Eco Max)
0
0~6
2 Fan Manual Switch
Fan Manual SW
(0:Auto 1:Mamual Adj)
0-3
3 Fan1 Manual Voltage
Fan Voltage Manual Adj Mode (0.1V)
* Effective only Fan Manual Switch = 1
0-255
4 Fan2 Manual Voltage
0-255
5 Fan3 Manual Voltage
0-255
6 Fan4 Manual Set
PWM Duty Ratio Manual Adj Mode
* Effective only Fan Manual Switch = 1
0-511
7 DAC OUT Stability
DAC Output update period setting
1: every second, 2 sec, 3: 3sec.
2
0-10
Содержание PLC-XT35
Страница 102: ... 102 IC Block Diagrams BA7078 Sync Seperator IC5321 FA7701V Switching Controller IC5641 ...
Страница 103: ... 103 IC Block Diagrams HIN202EIB RS 232C Driver IC3801 L3E01060 Level Shift IC2501 IC2531 IC2561 ...
Страница 104: ... 104 IC Block Diagrams L3E06150 Sample Hold IC501 IC531 IC561 L3E07111 Digital Gamma Shift LCD Driver IC401 ...
Страница 105: ... 105 IC Block Diagrams LM4889 Audio Output IC5121 NJW1141 Audio Control IC5001 ...
Страница 106: ... 106 IC Block Diagrams TE7783 Parallel I O Expander IC1801 PW190 Scan Converter System Control IC301 ...
Страница 107: ... 107 IC Block Diagrams CXA2229 Video SW Sync IC101 CXD3815 Video Decoder IC3101 ...
Страница 108: ... 108 IC Block Diagrams THS7347IPHPR PC1 PC2 SW IC5201 ...
Страница 134: ... 134 Mechanical Parts List KP3 XT3500 KP3 XT35L00 Condenser lens out assembly M07 L15 Relay lens out assembly L19 M08 ...
Страница 139: ... 139 Mechanical Parts List KP3 XT3500 KP3 XT35L00 ...
Страница 140: ... KP3A Nov 2007 DC 350 Printed in Japan SANYO Electric Co Ltd ...
Страница 152: ...A10 SCH_KP3A 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 A B C D E F G H I J K L A B C D E F G H I J K L NO DATA ...