- 24 -
To enter the service mode
To enter the “Service Mode”, press and hold the
MENU
and
IMAGE button
on the projector at the same time for
more than 3 seconds, or press and hold the
MENU button
on the remote control unit for more than 20 seconds.
The service menu appears on the screen as follows.
To adjust service data
Select the adjustment group no. by pressing the
MENU
or
IMAGE button
, and select the adjustment item no. by
pressing the pointer
UP
or
DOWN button
, and change the data value by pressing the
VOLUME –
or
button
. Refer to the “Service Adjustment Data Table” for further description of adjustment group no., item no. and
data value.
To exit the service mode
To exit the service mode, press the
POWER ON-OFF button
on the projector or remote control unit.
Service Adjustment Menu Operation
Service Mode
Input
Input 1
Group
No.
Data
0
0
280
1.00
20
Ver
IC802 on the main board stores the data for the serv-
ice adjustments, and should not be replaced except for
the case of defective device.
If replaced, it should be performed the re-adjustments
following to the “Electrical Adjustments”.
The data of lamp replacement monitor timer is stored
in the IC802.
Please note that the lamp replace counter is reset
when the memory IC (IC802) is replaced.
(Lamp replace counter can not be set to the previous
value.)
●
Caution of Main Board replacement (in the case
IC802 is not defective)
When the main board is replaced, IC802 should be
replaced with the one on previous main board. After
replacement, it should be required to perform the re-
adjustments following to the “Electrical Adjustments”.
In this case, the lamp replace counter can be kept the
value as before.
●
Caution to memory IC replacement
When IC802 is replaced with new one, the CPU writes
down the default data of the service adjustments to the
replaced IC, refer to the service adjustment table. As
these data are not the same data as factory shipped
data, it should be required to perform the re-adjust-
ments following to the “Electrical Adjustments”.
Please note that the lamp replace counter is reset.
Before IC802 is replaced with new one, take a memo
for the value of group/item no.
"290 - 0"
of the service
adjustment data table, and after replacing IC802
change the value of group/item no.
"290 - 1"
to the
same data with the memo.
●
Memory IC Replacement
Group No.
Data value
Item No.
Electrical Adjustments
Содержание PLC-XP57L
Страница 63: ... 63 IC Block Diagrams CXD3807 AV A D IC9201 EDD2516 DDR Memory IC1301 IC1311 IC1321 IC1331 ...
Страница 64: ... 64 FA5502M P F Controller IC601 IC Block Diagrams EM638325TS DDR Memory IC1801 ...
Страница 66: ... 66 IC Block Diagrams PW388 System Control Scan Converter IC301 STR Z2156A Power Switching IC651 ...
Страница 67: ... 67 IC Block Diagrams TA1370FG Sync Separator Frequency Counter IC3231 TIC81592 I O Expander IC4801 Divide ...
Страница 102: ...KE6 XP57L00 102 Optical Parts List 58 43 43 45 45 55 43 43 ...
Страница 104: ... KE6AL JUN 2006 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 122: ...Diagrams Drawings KE6AL ...