-83-
Troubleshooting
This projector provides a function to get the error information of the projector by using the RS-3C serial port for the
power failure diagnosis.
The further error information of the power failure and fan failure can be found out by using this function.
Diagnosis procedure
1
Connect a RS-3C serial cross cable to CONTROL PORT on the projector and serial port on the PC.
2
Launch a communication software "Hyper terminal" provided with PC and setup the communication condition as
follows;
Baud rate
: 9600 / 1900 bps
Parity check
: none
Stop bit
: 1
Flow control
: none
Data bit
: 8
3
Turn on the projector. Check that the LED shows a
power failure. (All the LEDs except LAMP LED are
blinking)
4
Type a diagnosis command of the power failure “CR
ALLPFAIL” and press a "ENTER" key within 1 second
on the command window of the software.
The error information will be listed on the window as
the right.
Check the status column. If “NG” is listed, the power
failure occurs on its signal line (Power Line Name). In
case of the right table, this error information means that
the power failure occurs on the 3.3V power supply on
the GAMMA (Digital Gamma) circuit on the main board
(GAMMA, 3.3V). Check if the parts connected to 3.3V
power supply line on the Gamma circuit are defective.
Also the error information may be listed multiple as the
below;
In the above case, kinds of causes are considered.
One is the power failure occurs on the multiple places
at the same time, other is a power failure affects mul-
tiple power supply lines even if the failure occurs on the
single place.
In the first case, Check if the parts connected to the mul-
tiple power supply lines are defective. In the later case,
determine a failure point referring to the power supply
flow chart on previous page. Basically, if the power fail-
ure occurs on the upper side of power supply, the power
failure is also detected on lower side of power supply
frequently. If the failure occurs on the lower side of power supply, it is lightly affected to the upper side of the power
supply. In the above case, because the failure occurs on the 6V power supply on the main board (MAIN, 6V), the
failure is also detected on the 5V power supply on the main board (MAIN, 5V).
* See "Power Failure Detection System" for further description of the Error Information.
CR ALLPFAIL
000 AD,
3.3V OK
000 KS, 3.3V OK
000 KS, 2.5V OK
000 KS, 1.8V OK
000 GAMMA, 3.3V NG
000 GAMMA, 2.5V OK
000 GAMMA, 1.8V OK
........ ............... ......... ......
Status
Error Information
(Signal Name)
Error
CR ALLPFAIL
000 AD,
3.3V OK
000 KS, 3.3V OK
........ ............... ......... ......
000 MAIN, 6V NG
000 GAMMA, 15.5V OK
........ ............... ......... ......
000 MAIN, 5V NG
Error
Diagnosis of Power Failure with RS-232C port
Содержание PLC-XM100
Страница 89: ... 89 74LVC14 Inverter IC5502 IC Block Diagrams AD8183 Analog SW IC2001 ...
Страница 91: ... 91 IC Block Diagrams BA7078 Sync Separator IC1011 CXA7009 S H IC501 IC531 IC561 ...
Страница 92: ... 92 IC Block Diagrams CXD3540 Digital Gamma Correction IC401 FA5502 P F Control IC601 ...
Страница 93: ... 93 IC Block Diagrams ISL98001 A D Converter IC2201 M62393 DAC IC7801 ...
Страница 94: ... 94 IC Block Diagrams NJM2671 Motor Controller IC5541 NJW1156 Audio Selector IC5001 ...
Страница 95: ... 95 IC Block Diagrams PIC18F67 PIC IC8801 PW392 Scaler IC301 ...
Страница 96: ... 96 IC Block Diagrams PW610 Keystone IC2301 STR A6079 Power switching IC603 ...
Страница 97: ... 97 IC Block Diagrams TE7783 I O Expander IC4801 STR Z2156 Power switching IC651 ...
Страница 98: ... 98 IC Block Diagrams THS7347 3 CH Analog SW IC5231 IC5271 TPA3123 Audio Output IC001 ...
Страница 105: ... 105 Parts Location Diagrams KA8 XM15000 KA8 XM150L00 KZ5 XM10000 KZ5 XM100L00 Mirror B assembly S07 S07 S07 L10 M11 ...
Страница 152: ... KA8AL Nov 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...